Uses of Package
com.powsybl.iidm.network
Package
Description
Base classes and default implementation of limit violation detectors.
Classes used for the security analysis distribution or simple forwarding
to other itools process(es).
Explicits the common interface for executing security analysis either in this preprocess
or by delegating it to other itools processes.
Sensitivity analysis API
Sensitivity analysis is a concrete calculation of impact factors from some network variables modification
to some network function values.
-
ClassDescriptionConverters mode used to known the sign of the active power of the HVDC line.A power network model.
-
-
-
-
-
ClassDescriptionA battery system.An equipment with two terminals.A bus is a set of equipments connected together through a closed switch.A dangling line to model boundaries (X nodes).This is the base class for all IIDM exporters.A power generator.A HVDC line connected to two HVDC converters on DC side.LCC converter station.A constant power load (fixed p0 and q0).A power network model.A shunt compensator.Static VAR compensator model.An equipment connection point in a substation topology.A Three Windings Power Transformer.Transformer legA tie line is an AC line sharing power between two neighbouring regional grids.VSC converter station.
-
ClassDescriptionA battery system.A bus is a set of equipments connected together through a closed switch.A dangling line to model boundaries (X nodes).A power generator.A HVDC line connected to two HVDC converters on DC side.LCC converter station.An AC line.A constant power load (fixed p0 and q0).A power network model.A shunt compensator.Static VAR compensator model.A Three Windings Power Transformer.A tie line is an AC line sharing power between two neighbouring regional grids.A two windings power transformer.A voltage level is a collection of equipments located in the same substation and at the same base voltage.VSC converter station.
-
-
-
ClassDescriptionA bus is a set of equipments connected together through a closed switch.Countries alpha-2 code.A dangling line to model boundaries (X nodes).This is the base class for all IIDM exporters.To create a generator, from a
VoltageLevel
instance call theVoltageLevel.newGenerator()
method to get a generator builder instance.This is the base class for all IIDM importers.A power network model.An equipment connection point in a substation topology.A voltage level is a collection of equipments located in the same substation and at the same base voltage.VSC converter station builder and adder. -
ClassDescriptionA dangling line to model boundaries (X nodes).To create a generator, from a
VoltageLevel
instance call theVoltageLevel.newGenerator()
method to get a generator builder instance.An object that is part of the network model and that is identified uniquely by aString
id.A substation is a collection of equipments located at a the same geographical site.An equipment connection point in a substation topology.A voltage level is a collection of equipments located in the same substation and at the same base voltage. -
ClassDescriptionHDVC type: VSC or LCCAn object that is part of the network model and that is identified uniquely by a
String
id. -
ClassDescriptionA dangling line to model boundaries (X nodes).A Three Windings Power Transformer.
-
ClassDescriptionA bus is a set of equipments connected together through a closed switch.An equipment that is part of a substation topology.A dangling line to model boundaries (X nodes).HVDC converter station.An object that is part of the network model and that is identified uniquely by a
String
id.A constant power load (fixed p0 and q0).A power network model.The kind of switch.An equipment connection point in a substation topology. -
ClassDescriptionAn equipment that is part of a substation topology.The energy source of a generator.HDVC type: VSC or LCCThe kind of switch.
-
ClassDescriptionA power generator.An object that is part of the network model and that is identified uniquely by a
String
id. -
ClassDescriptionAn equipment that is part of a substation topology.A dangling line to model boundaries (X nodes).A power network model.An equipment connection point in a substation topology.A tie line is an AC line sharing power between two neighbouring regional grids.
-
ClassDescriptionA dangling line to model boundaries (X nodes).An AC line.A power network model.A substation is a collection of equipments located at a the same geographical site.
-
-
-
ClassDescriptionAn object that is part of the network model and that is identified uniquely by a
String
id.A power network model. -
-
-
-
-
ClassDescriptionCountries alpha-2 code.A substation is a collection of equipments located at a the same geographical site.
-
ClassDescriptionThis is the base class for all IIDM importers.A power network model.
-
-
ClassDescriptionCountries alpha-2 code.An object that is part of the network model and that is identified uniquely by a
String
id. -
ClassDescriptionCountries alpha-2 code.An object that is part of the network model and that is identified uniquely by a
String
id. -
-
ClassDescriptionA power network model.Static VAR compensator model.VSC converter station.
-
-
ClassDescriptionA power network model.A Three Windings Power Transformer.Transformer legA two windings power transformer.
-
ClassDescriptionA bus is a set of equipments connected together through a closed switch.A busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.An equipment that is part of a substation topology.An AC line.To create a new AC line, from a
Network
instance call theNetwork.newLine()
method to get a line builder instance.A power network model.The kind of switch.A voltage level is a collection of equipments located in the same substation and at the same base voltage. -
ClassDescriptionA battery system.An equipment with two terminals.A dangling line to model boundaries (X nodes).A power generator.A equipment with one terminal.A constant power load (fixed p0 and q0).A power network model.A shunt compensator.Static VAR compensator model.A switch to connect equipments in a substation.An equipment connection point in a substation topology.
-
ClassDescriptionA bus is a set of equipments connected together through a closed switch.A busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.An equipment that is part of a substation topology.A power generator.An object that is part of the network model and that is identified uniquely by a
String
id.A power network model.A shunt compensator.The kind of topology.A voltage level is a collection of equipments located in the same substation and at the same base voltage. -
ClassDescriptionA battery system.To create a battery, from a
VoltageLevel
instance call theVoltageLevel.newBattery()
method to get a battery builder instance.An equipment with two terminals.A bus is a set of equipments connected together through a closed switch.A busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.A set of connected bus in the network.An equipment that is part of a substation topology.Countries alpha-2 code.Current limits are defined by: A permanent limit (A) Any number of temporary limits.A dangling line to model boundaries (X nodes).The energy source of a generator.Exponential load model.This is the base class for all IIDM exporters.A power generator.To create a generator, from aVoltageLevel
instance call theVoltageLevel.newGenerator()
method to get a generator builder instance.HVDC converter station.HDVC type: VSC or LCCHVDC converter station builder and adder.A HVDC line connected to two HVDC converters on DC side.Converters mode used to known the sign of the active power of the HVDC line.HVDC line builder and adder.An object that is part of the network model and that is identified uniquely by aString
id.Generic configuration for network importing.This is the base class for all IIDM importers.A equipment with one terminal.LCC converter station.LCC converter station builder and adder.Harmonic filter.An AC line.To create a new AC line, from aNetwork
instance call theNetwork.newLine()
method to get a line builder instance.A constant power load (fixed p0 and q0).To create a load, from aVoltageLevel
instance call theVoltageLevel.newLoad()
method to get a load builder instance.Temporary current limit.Generator
reactive limits that does not depend of the active power.A power network model.A global bus/breaker view of the network.A global bus view of the network.Just being able to name method create et not createNetwork.An overload management system.A phase tap changer that is associated to a transformer to control the phase.Interface for classes responsible for building a single step.A ratio tap changer that is associated to a transformer to control the voltage or reactive power.Interface for classes responsible for building a single step.A reactive capability curve to define reactive limits of aGenerator
or
Battery
that depends of the active power.
A point of the reactive capability curve, for a given active power the minimal and the maximal value for the reactive power.Base class forGenerator
reactive limits.A shunt compensator.To create a shunt compensator, from aVoltageLevel
instance call theVoltageLevel.newShuntCompensator()
method to get a shunt compensator builder instance.Static VAR compensator model.A substation is a collection of equipments located at a the same geographical site.To create a substation, from aNetwork
instance call theNetwork.newSubstation()
method to get a substation builder instance.A switch to connect equipments in a substation.The kind of switch.Generic adder interface of the tap changer.Set of methods to build a new step for a tap changer.Contains methods to build and replace the list of steps of an existing tap changer.An equipment connection point in a substation topology.A bus/breaker view of the terminal.A bus view of the terminal.A node/breaker view of the terminal.Topology traversal handlerA Three Windings Power Transformer.Transformer legA tie line is an AC line sharing power between two neighbouring regional grids.The kind of topology.The level of topology.A two windings power transformer.This class provides methods to manage variants of the network (create and remove a variant, set the working variant, etc).A voltage level is a collection of equipments located in the same substation and at the same base voltage.A bus/breaker view of the topology.A bus view of the substation topology.A node/breaker view of the topology.VSC converter station.VSC converter station builder and adder.ZIP (polynomial) load model. -
-
ClassDescriptionAn equipment with two terminals.A bus is a set of equipments connected together through a closed switch.An equipment that is part of a substation topology.An object that is part of the network model and that is identified uniquely by a
String
id.A equipment with one terminal.A power network model.An equipment connection point in a substation topology.A Three Windings Power Transformer.A voltage level is a collection of equipments located in the same substation and at the same base voltage. -
ClassDescriptionAn equipment that is part of a substation topology.An object that is part of the network model and that is identified uniquely by a
String
id. -
ClassDescriptionAn object that is part of the network model and that is identified uniquely by a
String
id.A power network model. -
ClassDescriptionA battery system.To create a battery, from a
VoltageLevel
instance call theVoltageLevel.newBattery()
method to get a battery builder instance.An equipment with two terminals.A busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.An equipment that is part of a substation topology.Countries alpha-2 code.Current limits are defined by: A permanent limit (A) Any number of temporary limits.A dangling line to model boundaries (X nodes).Exponential load model.A power generator.HVDC converter station.A HVDC line connected to two HVDC converters on DC side.Converters mode used to known the sign of the active power of the HVDC line.HVDC line builder and adder.An object that is part of the network model and that is identified uniquely by aString
id.A equipment with one terminal.LCC converter station.An AC line.To create a new AC line, from aNetwork
instance call theNetwork.newLine()
method to get a line builder instance.A constant power load (fixed p0 and q0).Temporary current limit.A power network model.A global bus/breaker view of the network.A global bus view of the network.An overload management system.Interface for classes responsible for building a single step when usingPhaseTapChangerStepsReplacer
.Interface for classes responsible for building a single step when usingRatioTapChangerStepsReplacer
.Base class forGenerator
reactive limits.A shunt compensator.Static VAR compensator model.A substation is a collection of equipments located at a the same geographical site.To create a substation, from aNetwork
instance call theNetwork.newSubstation()
method to get a substation builder instance.A switch to connect equipments in a substation.Contains methods to build and replace the list of steps of an existing tap changer.An equipment connection point in a substation topology.A Three Windings Power Transformer.A tie line is an AC line sharing power between two neighbouring regional grids.The kind of topology.A two windings power transformer.This class provides methods to manage variants of the network (create and remove a variant, set the working variant, etc).A voltage level is a collection of equipments located in the same substation and at the same base voltage.VSC converter station.ZIP (polynomial) load model. -
ClassDescriptionA battery system.An equipment with two terminals.A busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.An equipment that is part of a substation topology.A dangling line to model boundaries (X nodes).A power generator.A HVDC line connected to two HVDC converters on DC side.An object that is part of the network model and that is identified uniquely by a
String
id.A equipment with one terminal.An AC line.A constant power load (fixed p0 and q0).A power network model.Static VAR compensator model.A substation is a collection of equipments located at a the same geographical site.An equipment connection point in a substation topology.A Three Windings Power Transformer.A two windings power transformer.A voltage level is a collection of equipments located in the same substation and at the same base voltage. -
ClassDescriptionAn object that is part of the network model and that is identified uniquely by a
String
id. -
-
ClassDescriptionA busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.A constant power load (fixed p0 and q0).A power network model.An equipment connection point in a substation topology.
-
-
ClassDescriptionAn equipment with two terminals.A bus is a set of equipments connected together through a closed switch.A busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.A dangling line to model boundaries (X nodes).HVDC converter station.An object that is part of the network model and that is identified uniquely by a
String
id.LCC converter station.An AC line.Temporary current limit.A power network model.A switch to connect equipments in a substation.An equipment connection point in a substation topology.A Three Windings Power Transformer.A tie line is an AC line sharing power between two neighbouring regional grids.A two windings power transformer.A voltage level is a collection of equipments located in the same substation and at the same base voltage.A node/breaker view of the topology. -
ClassDescriptionA HVDC line connected to two HVDC converters on DC side.A equipment with one terminal.An AC line.A power network model.A substation is a collection of equipments located at a the same geographical site.A Three Windings Power Transformer.A two windings power transformer.A voltage level is a collection of equipments located in the same substation and at the same base voltage.
-
ClassDescriptionA bus is a set of equipments connected together through a closed switch.An equipment that is part of a substation topology.Current limits are defined by: A permanent limit (A) Any number of temporary limits.This is the base class for all IIDM exporters.An object that is part of the network model and that is identified uniquely by a
String
id.This is the base class for all IIDM importers.LCC converter station.LCC converter station builder and adder.A power network model.Static VAR compensator model.A switch to connect equipments in a substation.An equipment connection point in a substation topology.A tie line is an AC line sharing power between two neighbouring regional grids.The kind of topology.The level of topology.A voltage level is a collection of equipments located in the same substation and at the same base voltage. -
-
ClassDescriptionA battery system.An equipment with two terminals.A busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.An equipment that is part of a substation topology.A power generator.A HVDC line connected to two HVDC converters on DC side.An object that is part of the network model and that is identified uniquely by a
String
id.A equipment with one terminal.An AC line.A constant power load (fixed p0 and q0).A power network model.Static VAR compensator model.A substation is a collection of equipments located at a the same geographical site.A Three Windings Power Transformer.A two windings power transformer.A voltage level is a collection of equipments located in the same substation and at the same base voltage. -
-
ClassDescriptionAn object that is part of the network model and that is identified uniquely by a
String
id.Temporary current limit. -
-
-
ClassDescriptionA battery system.A bus is a set of equipments connected together through a closed switch.A busbar section, a non impedant element used in a node/breaker substation topology to connect equipments.A dangling line to model boundaries (X nodes).A power generator.An AC line.A constant power load (fixed p0 and q0).A power network model.A shunt compensator.Static VAR compensator model.A Three Windings Power Transformer.A two windings power transformer.
-
ClassDescriptionA bus is a set of equipments connected together through a closed switch.A power generator.An AC line.A power network model.A shunt compensator.Static VAR compensator model.A Three Windings Power Transformer.A tie line is an AC line sharing power between two neighbouring regional grids.A two windings power transformer.
-
-
ClassDescriptionThis is the base class for all IIDM exporters.This is the base class for all IIDM importers.A power network model.
-
ClassDescriptionThis is the base class for all IIDM importers.A power network model.
-
ClassDescriptionThis is the base class for all IIDM exporters.This is the base class for all IIDM importers.A power network model.
-
-
ClassDescriptionAn equipment with two terminals.A bus is a set of equipments connected together through a closed switch.Countries alpha-2 code.A power network model.A Three Windings Power Transformer.A voltage level is a collection of equipments located in the same substation and at the same base voltage.
-
ClassDescriptionAn equipment with two terminals.A bus is a set of equipments connected together through a closed switch.A power network model.A Three Windings Power Transformer.A voltage level is a collection of equipments located in the same substation and at the same base voltage.
-
-
-
-
-
ClassDescriptionAn object that is part of the network model and that is identified uniquely by a
String
id. -
-
ClassDescriptionCurrent limits are defined by: A permanent limit (A) Any number of temporary limits.Temporary current limit.
-
-
-
-
ClassDescriptionAn equipment with two terminals.A bus is a set of equipments connected together through a closed switch.A dangling line to model boundaries (X nodes).This is the base class for all IIDM exporters.This is the base class for all IIDM importers.A power network model.A switch to connect equipments in a substation.
-
-