Method Summary
double
If the transformer side 1 is earthed, depending on
WindingConnectionType
side 1, it represents the
resistance part of the impedance to ground.
double
If the transformer side 2 is earthed, depending on
WindingConnectionType
side 2, it represents the
resistance part of the impedance to ground.
double
If the transformer side 1 is earthed, depending on
WindingConnectionType
side 1, it represents the
reactance part of the impedance to ground.
double
If the transformer side 2 is earthed, depending on
WindingConnectionType
side 2, it represents the
reactance part of the impedance to ground.
Return the name of this extension.
double
The zero sequence resistance of the two windings transformer.
double
The zero sequence reactance of the two windings transformer.
boolean
Free fluxes set to true means that the magnetizing impedance Zm is infinite, i.e. fluxes are free.
void
void
void
void
void
void
void
void
void
-
-
Method Details
-
-
getRz
double getRz()
The zero sequence resistance of the two windings transformer.
-
setRz
void setRz(double rz)
-
getXz
double getXz()
The zero sequence reactance of the two windings transformer.
-
setXz
void setXz(double xz)
-
isFreeFluxes
boolean isFreeFluxes()
Free fluxes set to true means that the magnetizing impedance Zm is infinite, i.e. fluxes are free.
-
setFreeFluxes
void setFreeFluxes(boolean freeFluxes)
-
-
-
-
-
getGroundingR1
double getGroundingR1()
If the transformer side 1 is earthed, depending on
WindingConnectionType
side 1, it represents the
resistance part of the impedance to ground.
-
setGroundingR1
void setGroundingR1(double groundingR1)
-
getGroundingR2
double getGroundingR2()
If the transformer side 2 is earthed, depending on
WindingConnectionType
side 2, it represents the
resistance part of the impedance to ground.
-
setGroundingR2
void setGroundingR2(double groundingR2)
-
getGroundingX1
double getGroundingX1()
If the transformer side 1 is earthed, depending on
WindingConnectionType
side 1, it represents the
reactance part of the impedance to ground.
-
setGroundingX1
void setGroundingX1(double groundingX1)
-
getGroundingX2
double getGroundingX2()
If the transformer side 2 is earthed, depending on
WindingConnectionType
side 2, it represents the
reactance part of the impedance to ground.
-
setGroundingX2
void setGroundingX2(double groundingX2)