Uses of Package
com.powsybl.action
Packages that use com.powsybl.action
Package
Description
Explicits the common interface for executing security analysis either in this preprocess
or by delegating it to other itools processes.
-
Classes in com.powsybl.action used by com.powsybl.actionClassDescriptionAn action to: change the P0 of a load or a dangling line , either by specifying a new absolute value (MW) or a relative change (MW). change the Q0 of a load or a dangling line, either by specifying a new absolute value (MVar) or a relative change (MVar).An action modifying the regulation of a two or three windings transformerAn action modifying the tap position of a two or three windings transformerAn action is taken according to an operator strategy when a condition occurs.A container for a list of actions.An action to: Change the interchange target of an area by specifying a new interchange target in MW.An action to: change the P0 of a load, either by specifying a new absolute value (MW) or a relative change (MW). change the Q0 of a load, either by specifying a new absolute value (MVar) or a relative change (MVar).An action to: change the targetP of a generator, either by specifying a new absolute value (MW) or a relative change (MW). enable or disable the generator voltage control. change targetQ of a generator (MVar).An action to modify HVDC parameters and/or operating mode.An action to: change the P0 of a load, either by specifying a new absolute value (MW) or a relative change (MW). change the Q0 of a load, either by specifying a new absolute value (MVar) or a relative change (MVar).An action consisting in an ordered list of actions.An action modifying the regulation of a phase-shifting transformerAn action changing the tap position of a phase-shifting transformer.An action activating or deactivating the regulation of a ratio transformerAn action modifying the tap position of a ratio transformerAn action to: change the regulationMode of a static var compensator, three options are available VOLTAGE, REACTIVE_POWER or OFF change voltageSetPoint to change the voltage setpoint if the regulation mode is set to VOLTAGE (kV) change reactivePowerSetpoint to change the reactive power setpoint if the regulation mode is set to REACTIVE_POWER (MVAR)An action opening or closing a switch.An action of opening or closing an equipment terminal(s).
-
Classes in com.powsybl.action used by com.powsybl.action.jsonClassDescriptionAn action to: change the P0 of a load or a dangling line , either by specifying a new absolute value (MW) or a relative change (MW). change the Q0 of a load or a dangling line, either by specifying a new absolute value (MVar) or a relative change (MVar).An action modifying the regulation of a two or three windings transformerAn action modifying the tap position of a two or three windings transformerA container for a list of actions.An action to: Change the interchange target of an area by specifying a new interchange target in MW.An action to: change the P0 of a load, either by specifying a new absolute value (MW) or a relative change (MW). change the Q0 of a load, either by specifying a new absolute value (MVar) or a relative change (MVar).An action to: change the targetP of a generator, either by specifying a new absolute value (MW) or a relative change (MW). enable or disable the generator voltage control. change targetQ of a generator (MVar).An action to modify HVDC parameters and/or operating mode.An action to: change the P0 of a load, either by specifying a new absolute value (MW) or a relative change (MW). change the Q0 of a load, either by specifying a new absolute value (MVar) or a relative change (MVar).An action consisting in an ordered list of actions.An action to: change the P0 of a load, by specifying its percentage change (which could be positive or negative). describe the impact of this change on the Q0 of a load, by specifying the qModificationStrategy.An action modifying the regulation of a phase-shifting transformerAn action changing the tap position of a phase-shifting transformer.An action activating or deactivating the regulation of a ratio transformerAn action modifying the tap position of a ratio transformerAn action to: change the regulationMode of a static var compensator, three options are available VOLTAGE, REACTIVE_POWER or OFF change voltageSetPoint to change the voltage setpoint if the regulation mode is set to VOLTAGE (kV) change reactivePowerSetpoint to change the reactive power setpoint if the regulation mode is set to REACTIVE_POWER (MVAR)An action opening or closing a switch.An action of opening or closing an equipment terminal(s).
-
Classes in com.powsybl.action used by com.powsybl.securityClassDescriptionAn action is taken according to an operator strategy when a condition occurs.
-
Classes in com.powsybl.action used by com.powsybl.security.executionClassDescriptionAn action is taken according to an operator strategy when a condition occurs.