A B C D E F G H I K L M N O P Q R S T U V W X Z 
All Classes All Packages

A

addLine(UcteLine) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
addLine(UcteLine) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
addLine(UcteLine) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
addNode(UcteNode) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
addNode(UcteNode) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
addNode(UcteNode) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
addRegulation(UcteRegulation) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
addRegulation(UcteRegulation) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
addRegulation(UcteRegulation) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
addTransformer(UcteTransformer) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
addTransformer(UcteTransformer) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
addTransformer(UcteTransformer) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
AL - com.powsybl.ucte.network.UcteCountryCode
 
ASYM - com.powsybl.ucte.network.UcteAngleRegulationType
Asymmetrical, Θ ≠ 90°.
AT - com.powsybl.ucte.network.UcteCountryCode
 

B

BA - com.powsybl.ucte.network.UcteCountryCode
 
BE - com.powsybl.ucte.network.UcteCountryCode
 
BG - com.powsybl.ucte.network.UcteCountryCode
 
BUSBAR_COUPLER_IN_OPERATION - com.powsybl.ucte.network.UcteElementStatus
2: busbar coupler in operation (definition: R=0, X=0, B=0).
BUSBAR_COUPLER_OUT_OF_OPERATION - com.powsybl.ucte.network.UcteElementStatus
7: busbar coupler out of operation (definition: R=0, X=0, B=0).
BY - com.powsybl.ucte.network.UcteCountryCode
 

C

C - com.powsybl.ucte.network.UctePowerPlantType
hard coal.
CH - com.powsybl.ucte.network.UcteCountryCode
 
checkAngleRegulation(UcteAngleRegulation, UcteElementId, Reporter) - Static method in class com.powsybl.ucte.network.UcteValidation
 
checkHeader(BufferedReader) - Method in class com.powsybl.ucte.network.io.UcteReader
 
checkPhaseRegulation(UctePhaseRegulation, UcteElementId, Reporter) - Static method in class com.powsybl.ucte.network.UcteValidation
 
checkValidLineCharacteristics(UcteLine, Reporter) - Static method in class com.powsybl.ucte.network.UcteValidation
 
checkValidTransformerCharacteristics(UcteTransformer, Reporter) - Static method in class com.powsybl.ucte.network.UcteValidation
 
com.powsybl.ucte.network - module com.powsybl.ucte.network
 
com.powsybl.ucte.network - package com.powsybl.ucte.network
 
com.powsybl.ucte.network.ext - package com.powsybl.ucte.network.ext
 
com.powsybl.ucte.network.io - package com.powsybl.ucte.network.io
 
compareTo(UcteElementId) - Method in class com.powsybl.ucte.network.UcteElementId
 
compareTo(UcteNode) - Method in class com.powsybl.ucte.network.UcteNode
 
compareTo(UcteNodeCode) - Method in class com.powsybl.ucte.network.UcteNodeCode
 
CZ - com.powsybl.ucte.network.UcteCountryCode
 

D

DE - com.powsybl.ucte.network.UcteCountryCode
 
DEBUG_SEVERITY - Static variable in class com.powsybl.ucte.network.ext.UcteReportConstants
 
DK - com.powsybl.ucte.network.UcteCountryCode
 
DU_LIMIT - Static variable in class com.powsybl.ucte.network.UcteValidation
 

E

equals(Object) - Method in class com.powsybl.ucte.network.UcteElementId
 
equals(Object) - Method in class com.powsybl.ucte.network.UcteNode
 
equals(Object) - Method in class com.powsybl.ucte.network.UcteNodeCode
 
EQUIVALENT - com.powsybl.ucte.network.UcteNodeStatus
1 = equivalent.
EQUIVALENT_ELEMENT_IN_OPERATION - com.powsybl.ucte.network.UcteElementStatus
1: equivalent element in operation.
EQUIVALENT_ELEMENT_OUT_OF_OPERATION - com.powsybl.ucte.network.UcteElementStatus
9: equivalent element out of operation.
error(String, String, String) - Method in class com.powsybl.ucte.network.UcteLogger
 
ERROR_SEVERITY - Static variable in class com.powsybl.ucte.network.ext.UcteReportConstants
 
ES - com.powsybl.ucte.network.UcteCountryCode
 

F

F - com.powsybl.ucte.network.UctePowerPlantType
further.
findByDate(String) - Static method in enum com.powsybl.ucte.network.UcteFormatVersion
 
FIRST - com.powsybl.ucte.network.UcteFormatVersion
 
fix(Reporter) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
fix(Reporter) - Method in class com.powsybl.ucte.network.UcteElement
 
fix(Reporter) - Method in class com.powsybl.ucte.network.UcteLine
 
fix(Reporter) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
fix(Reporter) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
fix(Reporter) - Method in class com.powsybl.ucte.network.UcteNode
 
fix(Reporter) - Method in interface com.powsybl.ucte.network.UcteRecord
 
fix(Reporter) - Method in class com.powsybl.ucte.network.UcteRegulation
 
fix(Reporter) - Method in class com.powsybl.ucte.network.UcteTransformer
 
FR - com.powsybl.ucte.network.UcteCountryCode
 
fromCode(int) - Static method in enum com.powsybl.ucte.network.UcteElementStatus
 
fromUcteCode(char) - Static method in enum com.powsybl.ucte.network.UcteCountryCode
 

G

G - com.powsybl.ucte.network.UctePowerPlantType
gas.
GB - com.powsybl.ucte.network.UcteCountryCode
 
getActiveLoad() - Method in class com.powsybl.ucte.network.UcteNode
Gets active load (MW).
getActivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
Gets active power generation (MW).
getAngleRegulation() - Method in class com.powsybl.ucte.network.UcteRegulation
Gets angle regulation (optional).
getBusbar() - Method in class com.powsybl.ucte.network.UcteNodeCode
Gets letter or figure for differentiating bus bars (optional).
getCode() - Method in enum com.powsybl.ucte.network.UcteElementStatus
 
getCode() - Method in class com.powsybl.ucte.network.UcteNode
Gets node code.
getComments() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getComments() - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getComments() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getConductance() - Method in class com.powsybl.ucte.network.UcteTransformer
Gets conductance G (μS).
getCurrentLimit() - Method in class com.powsybl.ucte.network.UcteElement
Gets current limit Ι (A).
getDate() - Method in enum com.powsybl.ucte.network.UcteFormatVersion
 
getDu() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Gets δu (%).
getDu() - Method in class com.powsybl.ucte.network.UctePhaseRegulation
Gets δu (%).
getElementName() - Method in class com.powsybl.ucte.network.UcteElement
Gets element name (optional).
getGeographicalName() - Method in class com.powsybl.ucte.network.UcteNode
Gets node geographical name.
getGeographicalSpot() - Method in class com.powsybl.ucte.network.UcteNodeCode
Gets short description of the geographical spot.
getId() - Method in class com.powsybl.ucte.network.UcteElement
Gets element id.
getId() - Method in class com.powsybl.ucte.network.UcteTransformer
Gets element id.
getLine(UcteElementId) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getLine(UcteElementId) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getLine(UcteElementId) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getLines() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getLines() - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getLines() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getMaximumPermissibleActivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
Gets maximum permissible active power generation (MW).
getMaximumPermissibleReactivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
Gets maximum permissible reactive power generation (MW).
getMinimumPermissibleActivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
Gets minimum permissible active power generation (MW).
getMinimumPermissibleReactivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
Gets minimum permissible reactive power generation (MW).
getN() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Gets number of taps.
getN() - Method in class com.powsybl.ucte.network.UctePhaseRegulation
Gets number of taps.
getName() - Method in class com.powsybl.ucte.network.ext.UcteSubstation
 
getName() - Method in class com.powsybl.ucte.network.ext.UcteVoltageLevel
 
getNode(UcteNodeCode) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getNode(UcteNodeCode) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getNode(UcteNodeCode) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getNodeCode1() - Method in class com.powsybl.ucte.network.UcteElementId
Gets node 1 code.
getNodeCode2() - Method in class com.powsybl.ucte.network.UcteElementId
Gets node 2 code.
getNodes() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getNodes() - Method in class com.powsybl.ucte.network.ext.UcteSubstation
 
getNodes() - Method in class com.powsybl.ucte.network.ext.UcteVoltageLevel
 
getNodes() - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getNodes() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getNominalPower() - Method in class com.powsybl.ucte.network.UcteTransformer
Gets nominal power (MVA).
getNominalPowerPrimaryControl() - Method in class com.powsybl.ucte.network.UcteNode
Gets nominal power for primary control (MW).
getNp() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Gets tap position.
getNp() - Method in class com.powsybl.ucte.network.UctePhaseRegulation
Gets tap position.
getOrderCode() - Method in class com.powsybl.ucte.network.UcteElementId
Gets order code (1, 2, 3 ... 9, A, B, C ...
getP() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Gets on load tap changer active power flow target (MW).
getPhaseRegulation() - Method in class com.powsybl.ucte.network.UcteRegulation
Gets phase regulation (optional).
getPowerPlantType() - Method in class com.powsybl.ucte.network.UcteNode
Gets power plant type.
getPrettyName() - Method in enum com.powsybl.ucte.network.UcteCountryCode
 
getRatedVoltage1() - Method in class com.powsybl.ucte.network.UcteTransformer
Gets rated voltage 1: non-regulated winding (kV).
getRatedVoltage2() - Method in class com.powsybl.ucte.network.UcteTransformer
Gets rated voltage 2: regulated winding (kV).
getReactance() - Method in class com.powsybl.ucte.network.UcteElement
Gets reactance X (Ω).
getReactiveLoad() - Method in class com.powsybl.ucte.network.UcteNode
Gets reactive load (MVar).
getReactivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
Gets reactive power generation (MVar).
getRegulation(UcteElementId) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getRegulation(UcteElementId) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getRegulation(UcteElementId) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getRegulations() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getRegulations() - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getRegulations() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getResistance() - Method in class com.powsybl.ucte.network.UcteElement
Gets resistance R (Ω).
getStaticOfPrimaryControl() - Method in class com.powsybl.ucte.network.UcteNode
Gets static of primary control (%).
getStatus() - Method in class com.powsybl.ucte.network.UcteElement
Gets element status.
getStatus() - Method in class com.powsybl.ucte.network.UcteNode
Gets node status.
getSubstation() - Method in class com.powsybl.ucte.network.ext.UcteVoltageLevel
 
getSubstations() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getSusceptance() - Method in class com.powsybl.ucte.network.UcteElement
Gets susceptance B (μS).
getTheta() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Gets Θ (°).
getThreePhaseShortCircuitPower() - Method in class com.powsybl.ucte.network.UcteNode
Gets three phase short circuit power (MVA).
getTransfoId() - Method in class com.powsybl.ucte.network.UcteRegulation
Gets transformer id.
getTransformer(UcteElementId) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getTransformer(UcteElementId) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getTransformer(UcteElementId) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getTransformers() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getTransformers() - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getTransformers() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getType() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Gets regulation type.
getTypeCode() - Method in class com.powsybl.ucte.network.UcteNode
Gets node type code.
getU() - Method in class com.powsybl.ucte.network.UctePhaseRegulation
Gets on load tap changer voltage target for node 2 (V2 or UL) (kV) (optional).
getUcteCode() - Method in enum com.powsybl.ucte.network.UcteCountryCode
 
getUcteCountryCode() - Method in class com.powsybl.ucte.network.UcteNodeCode
Gets UCTE country code.
getVersion() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getVersion() - Method in interface com.powsybl.ucte.network.UcteNetwork
 
getVersion() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
getVoltageLevel() - Method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
Gets the voltage level (kV).
getVoltageLevel(UcteNodeCode) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
getVoltageLevelCode() - Method in class com.powsybl.ucte.network.UcteNodeCode
Gets voltage level.
getVoltageLevels() - Method in class com.powsybl.ucte.network.ext.UcteSubstation
 
getVoltageReference() - Method in class com.powsybl.ucte.network.UcteNode
Gets voltage reference value (0 not allowed) in kV.
getXrRatio() - Method in class com.powsybl.ucte.network.UcteNode
Gets X/R ratio.
GR - com.powsybl.ucte.network.UcteCountryCode
 

H

H - com.powsybl.ucte.network.UctePowerPlantType
hydro.
hashCode() - Method in class com.powsybl.ucte.network.UcteElementId
 
hashCode() - Method in class com.powsybl.ucte.network.UcteNode
 
hashCode() - Method in class com.powsybl.ucte.network.UcteNodeCode
 
HR - com.powsybl.ucte.network.UcteCountryCode
 
HU - com.powsybl.ucte.network.UcteCountryCode
 

I

INFO_SEVERITY - Static variable in class com.powsybl.ucte.network.ext.UcteReportConstants
 
isGenerator() - Method in class com.powsybl.ucte.network.UcteNode
 
isRegulatingFrequency() - Method in class com.powsybl.ucte.network.UcteNode
 
isRegulatingVoltage() - Method in class com.powsybl.ucte.network.UcteNode
 
isUcteCountryCode(char) - Static method in enum com.powsybl.ucte.network.UcteCountryCode
 
isUcteElementId(String) - Static method in class com.powsybl.ucte.network.UcteElementId
 
isUcteNodeId(String) - Static method in class com.powsybl.ucte.network.UcteNodeCode
 
isVoltageLevelCode(char) - Static method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
 
IT - com.powsybl.ucte.network.UcteCountryCode
 

K

KS - com.powsybl.ucte.network.UcteCountryCode
 

L

L - com.powsybl.ucte.network.UctePowerPlantType
lignite.
LT - com.powsybl.ucte.network.UcteCountryCode
 
LU - com.powsybl.ucte.network.UcteCountryCode
 

M

MA - com.powsybl.ucte.network.UcteCountryCode
 
MD - com.powsybl.ucte.network.UcteCountryCode
 
ME - com.powsybl.ucte.network.UcteCountryCode
 
MK - com.powsybl.ucte.network.UcteCountryCode
 

N

N - com.powsybl.ucte.network.UctePowerPlantType
nuclear.
N_LIMIT - Static variable in class com.powsybl.ucte.network.UcteValidation
 
NL - com.powsybl.ucte.network.UcteCountryCode
 
NO - com.powsybl.ucte.network.UcteCountryCode
 

O

O - com.powsybl.ucte.network.UctePowerPlantType
oil.

P

parseUcteElementId(String) - Static method in class com.powsybl.ucte.network.UcteElementId
 
parseUcteNodeCode(String) - Static method in class com.powsybl.ucte.network.UcteNodeCode
Convert a string into a UcteNodeCode if possible, i.e. the string is compatible with the ucteNodeCode format
PL - com.powsybl.ucte.network.UcteCountryCode
 
PQ - com.powsybl.ucte.network.UcteNodeTypeCode
0 = P and Q constant (PQ node).
PT - com.powsybl.ucte.network.UcteCountryCode
 
PU - com.powsybl.ucte.network.UcteNodeTypeCode
2 = P and U constant (PU node).

Q

QT - com.powsybl.ucte.network.UcteNodeTypeCode
1 = Q and θ constant.

R

REACTANCE_EPS - Static variable in class com.powsybl.ucte.network.UcteValidation
 
read(BufferedReader, Reporter) - Method in class com.powsybl.ucte.network.io.UcteReader
 
REAL - com.powsybl.ucte.network.UcteNodeStatus
0 = real.
REAL_ELEMENT_IN_OPERATION - com.powsybl.ucte.network.UcteElementStatus
0: real element in operation (R, X only positive values permitted).
REAL_ELEMENT_OUT_OF_OPERATION - com.powsybl.ucte.network.UcteElementStatus
8: real element out of operation (R, X only positive values permitted).
RO - com.powsybl.ucte.network.UcteCountryCode
 
RS - com.powsybl.ucte.network.UcteCountryCode
 
RU - com.powsybl.ucte.network.UcteCountryCode
 

S

SE - com.powsybl.ucte.network.UcteCountryCode
 
SECOND - com.powsybl.ucte.network.UcteFormatVersion
 
setActiveLoad(double) - Method in class com.powsybl.ucte.network.UcteNode
Gets active load (MW).
setActivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets active power generation (MW).
setAngleRegulation(UcteAngleRegulation) - Method in class com.powsybl.ucte.network.UcteRegulation
Sets angle regulation (optional).
setBusbar(Character) - Method in class com.powsybl.ucte.network.UcteNodeCode
Sets letter or figure for differentiating bus bars (optional).
setCode(UcteNodeCode) - Method in class com.powsybl.ucte.network.UcteNode
Sets node code.
setConductance(double) - Method in class com.powsybl.ucte.network.UcteTransformer
Sets conductance G (μS).
setCurrentLimit(Integer) - Method in class com.powsybl.ucte.network.UcteElement
Sets current limit Ι (A).
setDu(double) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Sets δu (%).
setDu(double) - Method in class com.powsybl.ucte.network.UctePhaseRegulation
Sets δu (%).
setElementName(String) - Method in class com.powsybl.ucte.network.UcteElement
Sets element name (optional).
setGeographicalName(String) - Method in class com.powsybl.ucte.network.UcteNode
Sets node geographical name.
setGeographicalSpot(String) - Method in class com.powsybl.ucte.network.UcteNodeCode
Sets short description of the geographical spot.
setMaximumPermissibleActivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets maximum permissible active power generation (MW).
setMaximumPermissibleReactivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets maximum permissible reactive power generation (MW).
setMinimumPermissibleActivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets minimum permissible active power generation (MW).
setMinimumPermissibleReactivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets minimum permissible reactive power generation (MW).
setN(Integer) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Sets number of taps.
setN(Integer) - Method in class com.powsybl.ucte.network.UctePhaseRegulation
Sets number of taps.
setNominalPower(double) - Method in class com.powsybl.ucte.network.UcteTransformer
Sets nominal power (MVA).
setNominalPowerPrimaryControl(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets nominal power for primary control (MW).
setNp(Integer) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Sets tap position.
setNp(Integer) - Method in class com.powsybl.ucte.network.UctePhaseRegulation
Sets tap position.
setOrderCode(char) - Method in class com.powsybl.ucte.network.UcteElementId
Sets order code (1, 2, 3 ... 9, A, B, C ...
setP(double) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Sets on load tap changer active power flow target (MW).
setPhaseRegulation(UctePhaseRegulation) - Method in class com.powsybl.ucte.network.UcteRegulation
Sets phase regulation (optional).
setPowerPlantType(UctePowerPlantType) - Method in class com.powsybl.ucte.network.UcteNode
Sets power plant type.
setRatedVoltage1(double) - Method in class com.powsybl.ucte.network.UcteTransformer
Sets rated voltage 1: non-regulated winding (kV).
setRatedVoltage2(double) - Method in class com.powsybl.ucte.network.UcteTransformer
Sets rated voltage 2: regulated winding (kV).
setReactance(double) - Method in class com.powsybl.ucte.network.UcteElement
Sets reactance X (Ω).
setReactiveLoad(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets reactive load (MVar).
setReactivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets reactive power generation (MVar).
setResistance(double) - Method in class com.powsybl.ucte.network.UcteElement
Sets resistance R (Ω).
setStaticOfPrimaryControl(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets static of primary control (%).
setStatus(UcteElementStatus) - Method in class com.powsybl.ucte.network.UcteElement
Sets element status.
setStatus(UcteNodeStatus) - Method in class com.powsybl.ucte.network.UcteNode
Sets node status.
setSusceptance(double) - Method in class com.powsybl.ucte.network.UcteElement
Sets susceptance B (μS).
setTheta(double) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Sets Θ (°).
setThreePhaseShortCircuitPower(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets three phase short circuit power (MVA).
setType(UcteAngleRegulationType) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
Sets regulation type.
setTypeCode(UcteNodeTypeCode) - Method in class com.powsybl.ucte.network.UcteNode
Sets node type code.
setU(double) - Method in class com.powsybl.ucte.network.UctePhaseRegulation
Sets on load tap changer voltage target for node 2 (V2 or UL) (kV) (optional).
setUcteCountryCode(UcteCountryCode) - Method in class com.powsybl.ucte.network.UcteNodeCode
Sets UCTE country code.
setVersion(UcteFormatVersion) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
 
setVersion(UcteFormatVersion) - Method in interface com.powsybl.ucte.network.UcteNetwork
 
setVersion(UcteFormatVersion) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
 
setVoltageLevelCode(UcteVoltageLevelCode) - Method in class com.powsybl.ucte.network.UcteNodeCode
Sets voltage level.
setVoltageReference(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets voltage reference value (0 not allowed) in kV.
setXrRatio(double) - Method in class com.powsybl.ucte.network.UcteNode
Sets X/R ratio.
SI - com.powsybl.ucte.network.UcteCountryCode
 
SK - com.powsybl.ucte.network.UcteCountryCode
 
SYMM - com.powsybl.ucte.network.UcteAngleRegulationType
Symmetrical.

T

THETA_ABS_LIMIT - Static variable in class com.powsybl.ucte.network.UcteValidation
 
toString() - Method in class com.powsybl.ucte.network.UcteElement
 
toString() - Method in class com.powsybl.ucte.network.UcteElementId
 
toString() - Method in class com.powsybl.ucte.network.UcteNode
 
toString() - Method in class com.powsybl.ucte.network.UcteNodeCode
 
TR - com.powsybl.ucte.network.UcteCountryCode
 
TRACE_SEVERITY - Static variable in class com.powsybl.ucte.network.ext.UcteReportConstants
 

U

UA - com.powsybl.ucte.network.UcteCountryCode
 
UcteAngleRegulation - Class in com.powsybl.ucte.network
 
UcteAngleRegulation(double, double, Integer, Integer, double, UcteAngleRegulationType) - Constructor for class com.powsybl.ucte.network.UcteAngleRegulation
 
UcteAngleRegulationType - Enum in com.powsybl.ucte.network
 
UcteCountryCode - Enum in com.powsybl.ucte.network
 
UcteElement - Class in com.powsybl.ucte.network
 
UcteElement(UcteElementId, UcteElementStatus, double, double, double, Integer, String) - Constructor for class com.powsybl.ucte.network.UcteElement
 
UcteElementId - Class in com.powsybl.ucte.network
 
UcteElementId(UcteNodeCode, UcteNodeCode, char) - Constructor for class com.powsybl.ucte.network.UcteElementId
 
UcteElementStatus - Enum in com.powsybl.ucte.network
 
UcteException - Exception in com.powsybl.ucte.network
 
UcteException() - Constructor for exception com.powsybl.ucte.network.UcteException
 
UcteException(String) - Constructor for exception com.powsybl.ucte.network.UcteException
 
UcteFormatVersion - Enum in com.powsybl.ucte.network
 
UcteIoException - Exception in com.powsybl.ucte.network.io
 
UcteIoException() - Constructor for exception com.powsybl.ucte.network.io.UcteIoException
 
UcteIoException(String) - Constructor for exception com.powsybl.ucte.network.io.UcteIoException
 
UcteLine - Class in com.powsybl.ucte.network
 
UcteLine(UcteElementId, UcteElementStatus, double, double, double, Integer, String) - Constructor for class com.powsybl.ucte.network.UcteLine
 
UcteLogger - Class in com.powsybl.ucte.network
 
UcteLogger() - Constructor for class com.powsybl.ucte.network.UcteLogger
 
UcteNetwork - Interface in com.powsybl.ucte.network
 
UcteNetworkExt - Class in com.powsybl.ucte.network.ext
 
UcteNetworkExt(UcteNetwork, double) - Constructor for class com.powsybl.ucte.network.ext.UcteNetworkExt
 
UcteNetworkImpl - Class in com.powsybl.ucte.network
 
UcteNetworkImpl() - Constructor for class com.powsybl.ucte.network.UcteNetworkImpl
 
UcteNode - Class in com.powsybl.ucte.network
 
UcteNode(UcteNodeCode, String, UcteNodeStatus, UcteNodeTypeCode, double, double, double, double, double, double, double, double, double, double, double, double, double, UctePowerPlantType) - Constructor for class com.powsybl.ucte.network.UcteNode
 
UcteNodeCode - Class in com.powsybl.ucte.network
 
UcteNodeCode(UcteCountryCode, String, UcteVoltageLevelCode, Character) - Constructor for class com.powsybl.ucte.network.UcteNodeCode
 
UcteNodeStatus - Enum in com.powsybl.ucte.network
Node status.
UcteNodeTypeCode - Enum in com.powsybl.ucte.network
Node type code.
UctePhaseRegulation - Class in com.powsybl.ucte.network
 
UctePhaseRegulation(double, Integer, Integer, double) - Constructor for class com.powsybl.ucte.network.UctePhaseRegulation
 
UctePowerPlantType - Enum in com.powsybl.ucte.network
Power plant type.
UcteReader - Class in com.powsybl.ucte.network.io
 
UcteReader() - Constructor for class com.powsybl.ucte.network.io.UcteReader
 
UcteRecord - Interface in com.powsybl.ucte.network
 
UcteRegulation - Class in com.powsybl.ucte.network
 
UcteRegulation(UcteElementId, UctePhaseRegulation, UcteAngleRegulation) - Constructor for class com.powsybl.ucte.network.UcteRegulation
 
UcteReportConstants - Class in com.powsybl.ucte.network.ext
 
UcteSubstation - Class in com.powsybl.ucte.network.ext
 
UcteSubstation(String, List<UcteVoltageLevel>) - Constructor for class com.powsybl.ucte.network.ext.UcteSubstation
 
UcteTransformer - Class in com.powsybl.ucte.network
 
UcteTransformer(UcteElementId, UcteElementStatus, double, double, double, Integer, String, double, double, double, double) - Constructor for class com.powsybl.ucte.network.UcteTransformer
 
UcteValidation - Class in com.powsybl.ucte.network
 
UcteVoltageLevel - Class in com.powsybl.ucte.network.ext
 
UcteVoltageLevel(String, UcteSubstation, Collection<UcteNodeCode>) - Constructor for class com.powsybl.ucte.network.ext.UcteVoltageLevel
 
UcteVoltageLevelCode - Enum in com.powsybl.ucte.network
 
UcteWriter - Class in com.powsybl.ucte.network.io
 
UcteWriter(UcteNetwork) - Constructor for class com.powsybl.ucte.network.io.UcteWriter
 
UT - com.powsybl.ucte.network.UcteNodeTypeCode
3 = U and θ constant (global slack node, only one in the whole network).

V

valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteAngleRegulationType
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteCountryCode
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteElementStatus
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteFormatVersion
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteNodeStatus
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteNodeTypeCode
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum com.powsybl.ucte.network.UctePowerPlantType
Returns the enum constant of this type with the specified name.
valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
Returns the enum constant of this type with the specified name.
values() - Static method in enum com.powsybl.ucte.network.UcteAngleRegulationType
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum com.powsybl.ucte.network.UcteCountryCode
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum com.powsybl.ucte.network.UcteElementStatus
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum com.powsybl.ucte.network.UcteFormatVersion
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum com.powsybl.ucte.network.UcteNodeStatus
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum com.powsybl.ucte.network.UcteNodeTypeCode
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum com.powsybl.ucte.network.UctePowerPlantType
Returns an array containing the constants of this enum type, in the order they are declared.
values() - Static method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
Returns an array containing the constants of this enum type, in the order they are declared.
VL_110 - com.powsybl.ucte.network.UcteVoltageLevelCode
5 110kV.
VL_120 - com.powsybl.ucte.network.UcteVoltageLevelCode
4 120kV.
VL_150 - com.powsybl.ucte.network.UcteVoltageLevelCode
3 150kV.
VL_220 - com.powsybl.ucte.network.UcteVoltageLevelCode
2 220kV.
VL_27 - com.powsybl.ucte.network.UcteVoltageLevelCode
7 27kV.
VL_330 - com.powsybl.ucte.network.UcteVoltageLevelCode
8 330kV.
VL_380 - com.powsybl.ucte.network.UcteVoltageLevelCode
1 380kV.
VL_500 - com.powsybl.ucte.network.UcteVoltageLevelCode
9 500kV.
VL_70 - com.powsybl.ucte.network.UcteVoltageLevelCode
6 70kV.
VL_750 - com.powsybl.ucte.network.UcteVoltageLevelCode
0 750kV.
voltageLevelCodeFromChar(char) - Static method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
 

W

W - com.powsybl.ucte.network.UctePowerPlantType
wind.
warn(String, String, String) - Method in class com.powsybl.ucte.network.UcteLogger
 
WARN_SEVERITY - Static variable in class com.powsybl.ucte.network.ext.UcteReportConstants
 
write(BufferedWriter) - Method in class com.powsybl.ucte.network.io.UcteWriter
 

X

XX - com.powsybl.ucte.network.UcteCountryCode
 

Z

ZERO_EPS - Static variable in class com.powsybl.ucte.network.UcteValidation
 
A B C D E F G H I K L M N O P Q R S T U V W X Z 
All Classes All Packages