A B C D E F G H I K L M N O P Q R S T U V W X Z
All Classes All Packages
All Classes All Packages
All Classes All Packages
A
- addLine(UcteLine) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- addLine(UcteLine) - Method in interface com.powsybl.ucte.network.UcteNetwork
- addLine(UcteLine) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- addNode(UcteNode) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- addNode(UcteNode) - Method in interface com.powsybl.ucte.network.UcteNetwork
- addNode(UcteNode) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- addRegulation(UcteRegulation) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- addRegulation(UcteRegulation) - Method in interface com.powsybl.ucte.network.UcteNetwork
- addRegulation(UcteRegulation) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- addTransformer(UcteTransformer) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- addTransformer(UcteTransformer) - Method in interface com.powsybl.ucte.network.UcteNetwork
- addTransformer(UcteTransformer) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- AL - com.powsybl.ucte.network.UcteCountryCode
- ASYM - com.powsybl.ucte.network.UcteAngleRegulationType
-
Asymmetrical, Θ ≠ 90°.
- AT - com.powsybl.ucte.network.UcteCountryCode
B
- BA - com.powsybl.ucte.network.UcteCountryCode
- BE - com.powsybl.ucte.network.UcteCountryCode
- BG - com.powsybl.ucte.network.UcteCountryCode
- BUSBAR_COUPLER_IN_OPERATION - com.powsybl.ucte.network.UcteElementStatus
-
2: busbar coupler in operation (definition: R=0, X=0, B=0).
- BUSBAR_COUPLER_OUT_OF_OPERATION - com.powsybl.ucte.network.UcteElementStatus
-
7: busbar coupler out of operation (definition: R=0, X=0, B=0).
- BY - com.powsybl.ucte.network.UcteCountryCode
C
- C - com.powsybl.ucte.network.UctePowerPlantType
-
hard coal.
- CH - com.powsybl.ucte.network.UcteCountryCode
- checkAngleRegulation(UcteAngleRegulation, UcteElementId, Reporter) - Static method in class com.powsybl.ucte.network.UcteValidation
- checkHeader(BufferedReader) - Method in class com.powsybl.ucte.network.io.UcteReader
- checkPhaseRegulation(UctePhaseRegulation, UcteElementId, Reporter) - Static method in class com.powsybl.ucte.network.UcteValidation
- checkValidLineCharacteristics(UcteLine, Reporter) - Static method in class com.powsybl.ucte.network.UcteValidation
- checkValidTransformerCharacteristics(UcteTransformer, Reporter) - Static method in class com.powsybl.ucte.network.UcteValidation
- com.powsybl.ucte.network - module com.powsybl.ucte.network
- com.powsybl.ucte.network - package com.powsybl.ucte.network
- com.powsybl.ucte.network.ext - package com.powsybl.ucte.network.ext
- com.powsybl.ucte.network.io - package com.powsybl.ucte.network.io
- compareTo(UcteElementId) - Method in class com.powsybl.ucte.network.UcteElementId
- compareTo(UcteNode) - Method in class com.powsybl.ucte.network.UcteNode
- compareTo(UcteNodeCode) - Method in class com.powsybl.ucte.network.UcteNodeCode
- CZ - com.powsybl.ucte.network.UcteCountryCode
D
- DE - com.powsybl.ucte.network.UcteCountryCode
- DK - com.powsybl.ucte.network.UcteCountryCode
- DU_LIMIT - Static variable in class com.powsybl.ucte.network.UcteValidation
E
- equals(Object) - Method in class com.powsybl.ucte.network.UcteElementId
- equals(Object) - Method in class com.powsybl.ucte.network.UcteNode
- equals(Object) - Method in class com.powsybl.ucte.network.UcteNodeCode
- EQUIVALENT - com.powsybl.ucte.network.UcteNodeStatus
-
1 = equivalent.
- EQUIVALENT_ELEMENT_IN_OPERATION - com.powsybl.ucte.network.UcteElementStatus
-
1: equivalent element in operation.
- EQUIVALENT_ELEMENT_OUT_OF_OPERATION - com.powsybl.ucte.network.UcteElementStatus
-
9: equivalent element out of operation.
- error(String, String, String) - Method in class com.powsybl.ucte.network.UcteLogger
- ES - com.powsybl.ucte.network.UcteCountryCode
F
- F - com.powsybl.ucte.network.UctePowerPlantType
-
further.
- findByDate(String) - Static method in enum com.powsybl.ucte.network.UcteFormatVersion
- FIRST - com.powsybl.ucte.network.UcteFormatVersion
- fix(Reporter) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- fix(Reporter) - Method in class com.powsybl.ucte.network.UcteElement
- fix(Reporter) - Method in class com.powsybl.ucte.network.UcteLine
- fix(Reporter) - Method in interface com.powsybl.ucte.network.UcteNetwork
- fix(Reporter) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- fix(Reporter) - Method in class com.powsybl.ucte.network.UcteNode
- fix(Reporter) - Method in interface com.powsybl.ucte.network.UcteRecord
- fix(Reporter) - Method in class com.powsybl.ucte.network.UcteRegulation
- fix(Reporter) - Method in class com.powsybl.ucte.network.UcteTransformer
- FR - com.powsybl.ucte.network.UcteCountryCode
- fromCode(int) - Static method in enum com.powsybl.ucte.network.UcteElementStatus
- fromUcteCode(char) - Static method in enum com.powsybl.ucte.network.UcteCountryCode
G
- G - com.powsybl.ucte.network.UctePowerPlantType
-
gas.
- GB - com.powsybl.ucte.network.UcteCountryCode
- getActiveLoad() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets active load (MW).
- getActivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets active power generation (MW).
- getAngleRegulation() - Method in class com.powsybl.ucte.network.UcteRegulation
-
Gets angle regulation (optional).
- getBusbar() - Method in class com.powsybl.ucte.network.UcteNodeCode
-
Gets letter or figure for differentiating bus bars (optional).
- getCode() - Method in enum com.powsybl.ucte.network.UcteElementStatus
- getCode() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets node code.
- getComments() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getComments() - Method in interface com.powsybl.ucte.network.UcteNetwork
- getComments() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getConductance() - Method in class com.powsybl.ucte.network.UcteTransformer
-
Gets conductance G (μS).
- getCurrentLimit() - Method in class com.powsybl.ucte.network.UcteElement
-
Gets current limit Ι (A).
- getDate() - Method in enum com.powsybl.ucte.network.UcteFormatVersion
- getDu() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Gets δu (%).
- getDu() - Method in class com.powsybl.ucte.network.UctePhaseRegulation
-
Gets δu (%).
- getElementName() - Method in class com.powsybl.ucte.network.UcteElement
-
Gets element name (optional).
- getGeographicalName() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets node geographical name.
- getGeographicalSpot() - Method in class com.powsybl.ucte.network.UcteNodeCode
-
Gets short description of the geographical spot.
- getId() - Method in class com.powsybl.ucte.network.UcteElement
-
Gets element id.
- getId() - Method in class com.powsybl.ucte.network.UcteTransformer
-
Gets element id.
- getLine(UcteElementId) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getLine(UcteElementId) - Method in interface com.powsybl.ucte.network.UcteNetwork
- getLine(UcteElementId) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getLines() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getLines() - Method in interface com.powsybl.ucte.network.UcteNetwork
- getLines() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getMaximumPermissibleActivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets maximum permissible active power generation (MW).
- getMaximumPermissibleReactivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets maximum permissible reactive power generation (MW).
- getMinimumPermissibleActivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets minimum permissible active power generation (MW).
- getMinimumPermissibleReactivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets minimum permissible reactive power generation (MW).
- getN() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Gets number of taps.
- getN() - Method in class com.powsybl.ucte.network.UctePhaseRegulation
-
Gets number of taps.
- getName() - Method in class com.powsybl.ucte.network.ext.UcteSubstation
- getName() - Method in class com.powsybl.ucte.network.ext.UcteVoltageLevel
- getNode(UcteNodeCode) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getNode(UcteNodeCode) - Method in interface com.powsybl.ucte.network.UcteNetwork
- getNode(UcteNodeCode) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getNodeCode1() - Method in class com.powsybl.ucte.network.UcteElementId
-
Gets node 1 code.
- getNodeCode2() - Method in class com.powsybl.ucte.network.UcteElementId
-
Gets node 2 code.
- getNodes() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getNodes() - Method in class com.powsybl.ucte.network.ext.UcteSubstation
- getNodes() - Method in class com.powsybl.ucte.network.ext.UcteVoltageLevel
- getNodes() - Method in interface com.powsybl.ucte.network.UcteNetwork
- getNodes() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getNominalPower() - Method in class com.powsybl.ucte.network.UcteTransformer
-
Gets nominal power (MVA).
- getNominalPowerPrimaryControl() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets nominal power for primary control (MW).
- getNp() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Gets tap position.
- getNp() - Method in class com.powsybl.ucte.network.UctePhaseRegulation
-
Gets tap position.
- getOrderCode() - Method in class com.powsybl.ucte.network.UcteElementId
-
Gets order code (1, 2, 3 ... 9, A, B, C ...
- getP() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Gets on load tap changer active power flow target (MW).
- getPhaseRegulation() - Method in class com.powsybl.ucte.network.UcteRegulation
-
Gets phase regulation (optional).
- getPowerPlantType() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets power plant type.
- getPrettyName() - Method in enum com.powsybl.ucte.network.UcteCountryCode
- getRatedVoltage1() - Method in class com.powsybl.ucte.network.UcteTransformer
-
Gets rated voltage 1: non-regulated winding (kV).
- getRatedVoltage2() - Method in class com.powsybl.ucte.network.UcteTransformer
-
Gets rated voltage 2: regulated winding (kV).
- getReactance() - Method in class com.powsybl.ucte.network.UcteElement
-
Gets reactance X (Ω).
- getReactiveLoad() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets reactive load (MVar).
- getReactivePowerGeneration() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets reactive power generation (MVar).
- getRegulation(UcteElementId) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getRegulation(UcteElementId) - Method in interface com.powsybl.ucte.network.UcteNetwork
- getRegulation(UcteElementId) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getRegulations() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getRegulations() - Method in interface com.powsybl.ucte.network.UcteNetwork
- getRegulations() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getResistance() - Method in class com.powsybl.ucte.network.UcteElement
-
Gets resistance R (Ω).
- getStaticOfPrimaryControl() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets static of primary control (%).
- getStatus() - Method in class com.powsybl.ucte.network.UcteElement
-
Gets element status.
- getStatus() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets node status.
- getSubstation() - Method in class com.powsybl.ucte.network.ext.UcteVoltageLevel
- getSubstations() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getSusceptance() - Method in class com.powsybl.ucte.network.UcteElement
-
Gets susceptance B (μS).
- getTheta() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Gets Θ (°).
- getThreePhaseShortCircuitPower() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets three phase short circuit power (MVA).
- getTransfoId() - Method in class com.powsybl.ucte.network.UcteRegulation
-
Gets transformer id.
- getTransformer(UcteElementId) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getTransformer(UcteElementId) - Method in interface com.powsybl.ucte.network.UcteNetwork
- getTransformer(UcteElementId) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getTransformers() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getTransformers() - Method in interface com.powsybl.ucte.network.UcteNetwork
- getTransformers() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getType() - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Gets regulation type.
- getTypeCode() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets node type code.
- getU() - Method in class com.powsybl.ucte.network.UctePhaseRegulation
-
Gets on load tap changer voltage target for node 2 (V2 or UL) (kV) (optional).
- getUcteCode() - Method in enum com.powsybl.ucte.network.UcteCountryCode
- getUcteCountryCode() - Method in class com.powsybl.ucte.network.UcteNodeCode
-
Gets UCTE country code.
- getVersion() - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getVersion() - Method in interface com.powsybl.ucte.network.UcteNetwork
- getVersion() - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- getVoltageLevel() - Method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
-
Gets the voltage level (kV).
- getVoltageLevel(UcteNodeCode) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- getVoltageLevelCode() - Method in class com.powsybl.ucte.network.UcteNodeCode
-
Gets voltage level.
- getVoltageLevels() - Method in class com.powsybl.ucte.network.ext.UcteSubstation
- getVoltageReference() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets voltage reference value (0 not allowed) in kV.
- getXrRatio() - Method in class com.powsybl.ucte.network.UcteNode
-
Gets X/R ratio.
- GR - com.powsybl.ucte.network.UcteCountryCode
H
- H - com.powsybl.ucte.network.UctePowerPlantType
-
hydro.
- hashCode() - Method in class com.powsybl.ucte.network.UcteElementId
- hashCode() - Method in class com.powsybl.ucte.network.UcteNode
- hashCode() - Method in class com.powsybl.ucte.network.UcteNodeCode
- HR - com.powsybl.ucte.network.UcteCountryCode
- HU - com.powsybl.ucte.network.UcteCountryCode
I
- isGenerator() - Method in class com.powsybl.ucte.network.UcteNode
- isRegulatingFrequency() - Method in class com.powsybl.ucte.network.UcteNode
- isRegulatingVoltage() - Method in class com.powsybl.ucte.network.UcteNode
- isUcteCountryCode(char) - Static method in enum com.powsybl.ucte.network.UcteCountryCode
- isUcteElementId(String) - Static method in class com.powsybl.ucte.network.UcteElementId
- isUcteNodeId(String) - Static method in class com.powsybl.ucte.network.UcteNodeCode
- isVoltageLevelCode(char) - Static method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
- IT - com.powsybl.ucte.network.UcteCountryCode
K
- KS - com.powsybl.ucte.network.UcteCountryCode
L
- L - com.powsybl.ucte.network.UctePowerPlantType
-
lignite.
- LT - com.powsybl.ucte.network.UcteCountryCode
- LU - com.powsybl.ucte.network.UcteCountryCode
M
- MA - com.powsybl.ucte.network.UcteCountryCode
- MD - com.powsybl.ucte.network.UcteCountryCode
- ME - com.powsybl.ucte.network.UcteCountryCode
- MK - com.powsybl.ucte.network.UcteCountryCode
N
- N - com.powsybl.ucte.network.UctePowerPlantType
-
nuclear.
- N_LIMIT - Static variable in class com.powsybl.ucte.network.UcteValidation
- NL - com.powsybl.ucte.network.UcteCountryCode
- NO - com.powsybl.ucte.network.UcteCountryCode
O
- O - com.powsybl.ucte.network.UctePowerPlantType
-
oil.
P
- parseUcteElementId(String) - Static method in class com.powsybl.ucte.network.UcteElementId
- parseUcteNodeCode(String) - Static method in class com.powsybl.ucte.network.UcteNodeCode
-
Convert a string into a UcteNodeCode if possible, i.e. the string is compatible with the ucteNodeCode format
- PL - com.powsybl.ucte.network.UcteCountryCode
- PQ - com.powsybl.ucte.network.UcteNodeTypeCode
-
0 = P and Q constant (PQ node).
- PT - com.powsybl.ucte.network.UcteCountryCode
- PU - com.powsybl.ucte.network.UcteNodeTypeCode
-
2 = P and U constant (PU node).
Q
- QT - com.powsybl.ucte.network.UcteNodeTypeCode
-
1 = Q and θ constant.
R
- REACTANCE_EPS - Static variable in class com.powsybl.ucte.network.UcteValidation
- read(BufferedReader, Reporter) - Method in class com.powsybl.ucte.network.io.UcteReader
- REAL - com.powsybl.ucte.network.UcteNodeStatus
-
0 = real.
- REAL_ELEMENT_IN_OPERATION - com.powsybl.ucte.network.UcteElementStatus
-
0: real element in operation (R, X only positive values permitted).
- REAL_ELEMENT_OUT_OF_OPERATION - com.powsybl.ucte.network.UcteElementStatus
-
8: real element out of operation (R, X only positive values permitted).
- RO - com.powsybl.ucte.network.UcteCountryCode
- RS - com.powsybl.ucte.network.UcteCountryCode
- RU - com.powsybl.ucte.network.UcteCountryCode
S
- SE - com.powsybl.ucte.network.UcteCountryCode
- SECOND - com.powsybl.ucte.network.UcteFormatVersion
- setActiveLoad(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Gets active load (MW).
- setActivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets active power generation (MW).
- setAngleRegulation(UcteAngleRegulation) - Method in class com.powsybl.ucte.network.UcteRegulation
-
Sets angle regulation (optional).
- setBusbar(Character) - Method in class com.powsybl.ucte.network.UcteNodeCode
-
Sets letter or figure for differentiating bus bars (optional).
- setCode(UcteNodeCode) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets node code.
- setConductance(double) - Method in class com.powsybl.ucte.network.UcteTransformer
-
Sets conductance G (μS).
- setCurrentLimit(Integer) - Method in class com.powsybl.ucte.network.UcteElement
-
Sets current limit Ι (A).
- setDu(double) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Sets δu (%).
- setDu(double) - Method in class com.powsybl.ucte.network.UctePhaseRegulation
-
Sets δu (%).
- setElementName(String) - Method in class com.powsybl.ucte.network.UcteElement
-
Sets element name (optional).
- setGeographicalName(String) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets node geographical name.
- setGeographicalSpot(String) - Method in class com.powsybl.ucte.network.UcteNodeCode
-
Sets short description of the geographical spot.
- setMaximumPermissibleActivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets maximum permissible active power generation (MW).
- setMaximumPermissibleReactivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets maximum permissible reactive power generation (MW).
- setMinimumPermissibleActivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets minimum permissible active power generation (MW).
- setMinimumPermissibleReactivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets minimum permissible reactive power generation (MW).
- setN(Integer) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Sets number of taps.
- setN(Integer) - Method in class com.powsybl.ucte.network.UctePhaseRegulation
-
Sets number of taps.
- setNominalPower(double) - Method in class com.powsybl.ucte.network.UcteTransformer
-
Sets nominal power (MVA).
- setNominalPowerPrimaryControl(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets nominal power for primary control (MW).
- setNp(Integer) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Sets tap position.
- setNp(Integer) - Method in class com.powsybl.ucte.network.UctePhaseRegulation
-
Sets tap position.
- setOrderCode(char) - Method in class com.powsybl.ucte.network.UcteElementId
-
Sets order code (1, 2, 3 ... 9, A, B, C ...
- setP(double) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Sets on load tap changer active power flow target (MW).
- setPhaseRegulation(UctePhaseRegulation) - Method in class com.powsybl.ucte.network.UcteRegulation
-
Sets phase regulation (optional).
- setPowerPlantType(UctePowerPlantType) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets power plant type.
- setRatedVoltage1(double) - Method in class com.powsybl.ucte.network.UcteTransformer
-
Sets rated voltage 1: non-regulated winding (kV).
- setRatedVoltage2(double) - Method in class com.powsybl.ucte.network.UcteTransformer
-
Sets rated voltage 2: regulated winding (kV).
- setReactance(double) - Method in class com.powsybl.ucte.network.UcteElement
-
Sets reactance X (Ω).
- setReactiveLoad(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets reactive load (MVar).
- setReactivePowerGeneration(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets reactive power generation (MVar).
- setResistance(double) - Method in class com.powsybl.ucte.network.UcteElement
-
Sets resistance R (Ω).
- setStaticOfPrimaryControl(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets static of primary control (%).
- setStatus(UcteElementStatus) - Method in class com.powsybl.ucte.network.UcteElement
-
Sets element status.
- setStatus(UcteNodeStatus) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets node status.
- setSusceptance(double) - Method in class com.powsybl.ucte.network.UcteElement
-
Sets susceptance B (μS).
- setTheta(double) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Sets Θ (°).
- setThreePhaseShortCircuitPower(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets three phase short circuit power (MVA).
- setType(UcteAngleRegulationType) - Method in class com.powsybl.ucte.network.UcteAngleRegulation
-
Sets regulation type.
- setTypeCode(UcteNodeTypeCode) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets node type code.
- setU(double) - Method in class com.powsybl.ucte.network.UctePhaseRegulation
-
Sets on load tap changer voltage target for node 2 (V2 or UL) (kV) (optional).
- setUcteCountryCode(UcteCountryCode) - Method in class com.powsybl.ucte.network.UcteNodeCode
-
Sets UCTE country code.
- setVersion(UcteFormatVersion) - Method in class com.powsybl.ucte.network.ext.UcteNetworkExt
- setVersion(UcteFormatVersion) - Method in interface com.powsybl.ucte.network.UcteNetwork
- setVersion(UcteFormatVersion) - Method in class com.powsybl.ucte.network.UcteNetworkImpl
- setVoltageLevelCode(UcteVoltageLevelCode) - Method in class com.powsybl.ucte.network.UcteNodeCode
-
Sets voltage level.
- setVoltageReference(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets voltage reference value (0 not allowed) in kV.
- setXrRatio(double) - Method in class com.powsybl.ucte.network.UcteNode
-
Sets X/R ratio.
- SI - com.powsybl.ucte.network.UcteCountryCode
- SK - com.powsybl.ucte.network.UcteCountryCode
- SYMM - com.powsybl.ucte.network.UcteAngleRegulationType
-
Symmetrical.
T
- THETA_ABS_LIMIT - Static variable in class com.powsybl.ucte.network.UcteValidation
- toString() - Method in class com.powsybl.ucte.network.UcteElement
- toString() - Method in class com.powsybl.ucte.network.UcteElementId
- toString() - Method in class com.powsybl.ucte.network.UcteNode
- toString() - Method in class com.powsybl.ucte.network.UcteNodeCode
- TR - com.powsybl.ucte.network.UcteCountryCode
U
- UA - com.powsybl.ucte.network.UcteCountryCode
- UcteAngleRegulation - Class in com.powsybl.ucte.network
- UcteAngleRegulation(double, double, Integer, Integer, double, UcteAngleRegulationType) - Constructor for class com.powsybl.ucte.network.UcteAngleRegulation
- UcteAngleRegulationType - Enum in com.powsybl.ucte.network
- UcteCountryCode - Enum in com.powsybl.ucte.network
- UcteElement - Class in com.powsybl.ucte.network
- UcteElement(UcteElementId, UcteElementStatus, double, double, double, Integer, String) - Constructor for class com.powsybl.ucte.network.UcteElement
- UcteElementId - Class in com.powsybl.ucte.network
- UcteElementId(UcteNodeCode, UcteNodeCode, char) - Constructor for class com.powsybl.ucte.network.UcteElementId
- UcteElementStatus - Enum in com.powsybl.ucte.network
- UcteException - Exception in com.powsybl.ucte.network
- UcteException() - Constructor for exception com.powsybl.ucte.network.UcteException
- UcteException(String) - Constructor for exception com.powsybl.ucte.network.UcteException
- UcteFormatVersion - Enum in com.powsybl.ucte.network
- UcteIoException - Exception in com.powsybl.ucte.network.io
- UcteIoException() - Constructor for exception com.powsybl.ucte.network.io.UcteIoException
- UcteIoException(String) - Constructor for exception com.powsybl.ucte.network.io.UcteIoException
- UcteLine - Class in com.powsybl.ucte.network
- UcteLine(UcteElementId, UcteElementStatus, double, double, double, Integer, String) - Constructor for class com.powsybl.ucte.network.UcteLine
- UcteLogger - Class in com.powsybl.ucte.network
- UcteLogger() - Constructor for class com.powsybl.ucte.network.UcteLogger
- UcteNetwork - Interface in com.powsybl.ucte.network
- UcteNetworkExt - Class in com.powsybl.ucte.network.ext
- UcteNetworkExt(UcteNetwork, double) - Constructor for class com.powsybl.ucte.network.ext.UcteNetworkExt
- UcteNetworkImpl - Class in com.powsybl.ucte.network
- UcteNetworkImpl() - Constructor for class com.powsybl.ucte.network.UcteNetworkImpl
- UcteNode - Class in com.powsybl.ucte.network
- UcteNode(UcteNodeCode, String, UcteNodeStatus, UcteNodeTypeCode, double, double, double, double, double, double, double, double, double, double, double, double, double, UctePowerPlantType) - Constructor for class com.powsybl.ucte.network.UcteNode
- UcteNodeCode - Class in com.powsybl.ucte.network
- UcteNodeCode(UcteCountryCode, String, UcteVoltageLevelCode, Character) - Constructor for class com.powsybl.ucte.network.UcteNodeCode
- UcteNodeStatus - Enum in com.powsybl.ucte.network
-
Node status.
- UcteNodeTypeCode - Enum in com.powsybl.ucte.network
-
Node type code.
- UctePhaseRegulation - Class in com.powsybl.ucte.network
- UctePhaseRegulation(double, Integer, Integer, double) - Constructor for class com.powsybl.ucte.network.UctePhaseRegulation
- UctePowerPlantType - Enum in com.powsybl.ucte.network
-
Power plant type.
- UcteReader - Class in com.powsybl.ucte.network.io
- UcteReader() - Constructor for class com.powsybl.ucte.network.io.UcteReader
- UcteRecord - Interface in com.powsybl.ucte.network
- UcteRegulation - Class in com.powsybl.ucte.network
- UcteRegulation(UcteElementId, UctePhaseRegulation, UcteAngleRegulation) - Constructor for class com.powsybl.ucte.network.UcteRegulation
- UcteSubstation - Class in com.powsybl.ucte.network.ext
- UcteSubstation(String, List<UcteVoltageLevel>) - Constructor for class com.powsybl.ucte.network.ext.UcteSubstation
- UcteTransformer - Class in com.powsybl.ucte.network
- UcteTransformer(UcteElementId, UcteElementStatus, double, double, double, Integer, String, double, double, double, double) - Constructor for class com.powsybl.ucte.network.UcteTransformer
- UcteValidation - Class in com.powsybl.ucte.network
- UcteVoltageLevel - Class in com.powsybl.ucte.network.ext
- UcteVoltageLevel(String, UcteSubstation, Collection<UcteNodeCode>) - Constructor for class com.powsybl.ucte.network.ext.UcteVoltageLevel
- UcteVoltageLevelCode - Enum in com.powsybl.ucte.network
- UcteWriter - Class in com.powsybl.ucte.network.io
- UcteWriter(UcteNetwork) - Constructor for class com.powsybl.ucte.network.io.UcteWriter
- UT - com.powsybl.ucte.network.UcteNodeTypeCode
-
3 = U and θ constant (global slack node, only one in the whole network).
V
- valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteAngleRegulationType
-
Returns the enum constant of this type with the specified name.
- valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteCountryCode
-
Returns the enum constant of this type with the specified name.
- valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteElementStatus
-
Returns the enum constant of this type with the specified name.
- valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteFormatVersion
-
Returns the enum constant of this type with the specified name.
- valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteNodeStatus
-
Returns the enum constant of this type with the specified name.
- valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteNodeTypeCode
-
Returns the enum constant of this type with the specified name.
- valueOf(String) - Static method in enum com.powsybl.ucte.network.UctePowerPlantType
-
Returns the enum constant of this type with the specified name.
- valueOf(String) - Static method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
-
Returns the enum constant of this type with the specified name.
- values() - Static method in enum com.powsybl.ucte.network.UcteAngleRegulationType
-
Returns an array containing the constants of this enum type, in the order they are declared.
- values() - Static method in enum com.powsybl.ucte.network.UcteCountryCode
-
Returns an array containing the constants of this enum type, in the order they are declared.
- values() - Static method in enum com.powsybl.ucte.network.UcteElementStatus
-
Returns an array containing the constants of this enum type, in the order they are declared.
- values() - Static method in enum com.powsybl.ucte.network.UcteFormatVersion
-
Returns an array containing the constants of this enum type, in the order they are declared.
- values() - Static method in enum com.powsybl.ucte.network.UcteNodeStatus
-
Returns an array containing the constants of this enum type, in the order they are declared.
- values() - Static method in enum com.powsybl.ucte.network.UcteNodeTypeCode
-
Returns an array containing the constants of this enum type, in the order they are declared.
- values() - Static method in enum com.powsybl.ucte.network.UctePowerPlantType
-
Returns an array containing the constants of this enum type, in the order they are declared.
- values() - Static method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
-
Returns an array containing the constants of this enum type, in the order they are declared.
- VL_110 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
5 110kV.
- VL_120 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
4 120kV.
- VL_150 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
3 150kV.
- VL_220 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
2 220kV.
- VL_27 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
7 27kV.
- VL_330 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
8 330kV.
- VL_380 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
1 380kV.
- VL_500 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
9 500kV.
- VL_70 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
6 70kV.
- VL_750 - com.powsybl.ucte.network.UcteVoltageLevelCode
-
0 750kV.
- voltageLevelCodeFromChar(char) - Static method in enum com.powsybl.ucte.network.UcteVoltageLevelCode
W
- W - com.powsybl.ucte.network.UctePowerPlantType
-
wind.
- warn(String, String, String) - Method in class com.powsybl.ucte.network.UcteLogger
- write(BufferedWriter) - Method in class com.powsybl.ucte.network.io.UcteWriter
X
- XX - com.powsybl.ucte.network.UcteCountryCode
Z
- ZERO_EPS - Static variable in class com.powsybl.ucte.network.UcteValidation
All Classes All Packages