Package com.google.protobuf
Class DescriptorProtos.FieldDescriptorProto.Builder
- java.lang.Object
-
- com.google.protobuf.AbstractMessageLite.Builder
-
- com.google.protobuf.AbstractMessage.Builder<BuilderT>
-
- com.google.protobuf.GeneratedMessageV3.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
-
- com.google.protobuf.DescriptorProtos.FieldDescriptorProto.Builder
-
- All Implemented Interfaces:
DescriptorProtos.FieldDescriptorProtoOrBuilder
,Message.Builder
,MessageLite.Builder
,MessageLiteOrBuilder
,MessageOrBuilder
,java.lang.Cloneable
- Enclosing class:
- DescriptorProtos.FieldDescriptorProto
public static final class DescriptorProtos.FieldDescriptorProto.Builder extends GeneratedMessageV3.Builder<DescriptorProtos.FieldDescriptorProto.Builder> implements DescriptorProtos.FieldDescriptorProtoOrBuilder
Protobuf typegoogle.protobuf.FieldDescriptorProto
-
-
Method Summary
All Methods Static Methods Instance Methods Concrete Methods Modifier and Type Method Description DescriptorProtos.FieldDescriptorProto
build()
Constructs the message based on the state of the Builder.DescriptorProtos.FieldDescriptorProto
buildPartial()
LikeMessageLite.Builder.build()
, but does not throw an exception if the message is missing required fields.DescriptorProtos.FieldDescriptorProto.Builder
clear()
Called by the initialization and clear code paths to allow subclasses to reset any of their builtin fields back to the initial values.DescriptorProtos.FieldDescriptorProto.Builder
clearDefaultValue()
optional string default_value = 7 [json_name = "defaultValue"];
DescriptorProtos.FieldDescriptorProto.Builder
clearExtendee()
optional string extendee = 2 [json_name = "extendee"];
DescriptorProtos.FieldDescriptorProto.Builder
clearJsonName()
optional string json_name = 10 [json_name = "jsonName"];
DescriptorProtos.FieldDescriptorProto.Builder
clearLabel()
optional .google.protobuf.FieldDescriptorProto.Label label = 4 [json_name = "label"];
DescriptorProtos.FieldDescriptorProto.Builder
clearName()
optional string name = 1 [json_name = "name"];
DescriptorProtos.FieldDescriptorProto.Builder
clearNumber()
optional int32 number = 3 [json_name = "number"];
DescriptorProtos.FieldDescriptorProto.Builder
clearOneofIndex()
optional int32 oneof_index = 9 [json_name = "oneofIndex"];
DescriptorProtos.FieldDescriptorProto.Builder
clearOptions()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
DescriptorProtos.FieldDescriptorProto.Builder
clearProto3Optional()
optional bool proto3_optional = 17 [json_name = "proto3Optional"];
DescriptorProtos.FieldDescriptorProto.Builder
clearType()
optional .google.protobuf.FieldDescriptorProto.Type type = 5 [json_name = "type"];
DescriptorProtos.FieldDescriptorProto.Builder
clearTypeName()
optional string type_name = 6 [json_name = "typeName"];
DescriptorProtos.FieldDescriptorProto
getDefaultInstanceForType()
Get an instance of the type with no fields set.java.lang.String
getDefaultValue()
optional string default_value = 7 [json_name = "defaultValue"];
ByteString
getDefaultValueBytes()
optional string default_value = 7 [json_name = "defaultValue"];
static Descriptors.Descriptor
getDescriptor()
Descriptors.Descriptor
getDescriptorForType()
Get the message's type's descriptor.java.lang.String
getExtendee()
optional string extendee = 2 [json_name = "extendee"];
ByteString
getExtendeeBytes()
optional string extendee = 2 [json_name = "extendee"];
java.lang.String
getJsonName()
optional string json_name = 10 [json_name = "jsonName"];
ByteString
getJsonNameBytes()
optional string json_name = 10 [json_name = "jsonName"];
DescriptorProtos.FieldDescriptorProto.Label
getLabel()
optional .google.protobuf.FieldDescriptorProto.Label label = 4 [json_name = "label"];
java.lang.String
getName()
optional string name = 1 [json_name = "name"];
ByteString
getNameBytes()
optional string name = 1 [json_name = "name"];
int
getNumber()
optional int32 number = 3 [json_name = "number"];
int
getOneofIndex()
optional int32 oneof_index = 9 [json_name = "oneofIndex"];
DescriptorProtos.FieldOptions
getOptions()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
DescriptorProtos.FieldOptions.Builder
getOptionsBuilder()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
DescriptorProtos.FieldOptionsOrBuilder
getOptionsOrBuilder()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
boolean
getProto3Optional()
optional bool proto3_optional = 17 [json_name = "proto3Optional"];
DescriptorProtos.FieldDescriptorProto.Type
getType()
optional .google.protobuf.FieldDescriptorProto.Type type = 5 [json_name = "type"];
java.lang.String
getTypeName()
optional string type_name = 6 [json_name = "typeName"];
ByteString
getTypeNameBytes()
optional string type_name = 6 [json_name = "typeName"];
boolean
hasDefaultValue()
optional string default_value = 7 [json_name = "defaultValue"];
boolean
hasExtendee()
optional string extendee = 2 [json_name = "extendee"];
boolean
hasJsonName()
optional string json_name = 10 [json_name = "jsonName"];
boolean
hasLabel()
optional .google.protobuf.FieldDescriptorProto.Label label = 4 [json_name = "label"];
boolean
hasName()
optional string name = 1 [json_name = "name"];
boolean
hasNumber()
optional int32 number = 3 [json_name = "number"];
boolean
hasOneofIndex()
optional int32 oneof_index = 9 [json_name = "oneofIndex"];
boolean
hasOptions()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
boolean
hasProto3Optional()
optional bool proto3_optional = 17 [json_name = "proto3Optional"];
boolean
hasType()
optional .google.protobuf.FieldDescriptorProto.Type type = 5 [json_name = "type"];
boolean
hasTypeName()
optional string type_name = 6 [json_name = "typeName"];
protected GeneratedMessageV3.FieldAccessorTable
internalGetFieldAccessorTable()
Get the FieldAccessorTable for this type.boolean
isInitialized()
Returns true if all required fields in the message and all embedded messages are set, false otherwise.DescriptorProtos.FieldDescriptorProto.Builder
mergeFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry)
LikeMessageLite.Builder.mergeFrom(CodedInputStream)
, but also parses extensions.DescriptorProtos.FieldDescriptorProto.Builder
mergeFrom(DescriptorProtos.FieldDescriptorProto other)
DescriptorProtos.FieldDescriptorProto.Builder
mergeFrom(Message other)
Mergeother
into the message being built.DescriptorProtos.FieldDescriptorProto.Builder
mergeOptions(DescriptorProtos.FieldOptions value)
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
DescriptorProtos.FieldDescriptorProto.Builder
mergeUnknownFields(UnknownFieldSet unknownFields)
Merge some unknown fields into theUnknownFieldSet
for this message.DescriptorProtos.FieldDescriptorProto.Builder
setDefaultValue(java.lang.String value)
optional string default_value = 7 [json_name = "defaultValue"];
DescriptorProtos.FieldDescriptorProto.Builder
setDefaultValueBytes(ByteString value)
optional string default_value = 7 [json_name = "defaultValue"];
DescriptorProtos.FieldDescriptorProto.Builder
setExtendee(java.lang.String value)
optional string extendee = 2 [json_name = "extendee"];
DescriptorProtos.FieldDescriptorProto.Builder
setExtendeeBytes(ByteString value)
optional string extendee = 2 [json_name = "extendee"];
DescriptorProtos.FieldDescriptorProto.Builder
setJsonName(java.lang.String value)
optional string json_name = 10 [json_name = "jsonName"];
DescriptorProtos.FieldDescriptorProto.Builder
setJsonNameBytes(ByteString value)
optional string json_name = 10 [json_name = "jsonName"];
DescriptorProtos.FieldDescriptorProto.Builder
setLabel(DescriptorProtos.FieldDescriptorProto.Label value)
optional .google.protobuf.FieldDescriptorProto.Label label = 4 [json_name = "label"];
DescriptorProtos.FieldDescriptorProto.Builder
setName(java.lang.String value)
optional string name = 1 [json_name = "name"];
DescriptorProtos.FieldDescriptorProto.Builder
setNameBytes(ByteString value)
optional string name = 1 [json_name = "name"];
DescriptorProtos.FieldDescriptorProto.Builder
setNumber(int value)
optional int32 number = 3 [json_name = "number"];
DescriptorProtos.FieldDescriptorProto.Builder
setOneofIndex(int value)
optional int32 oneof_index = 9 [json_name = "oneofIndex"];
DescriptorProtos.FieldDescriptorProto.Builder
setOptions(DescriptorProtos.FieldOptions value)
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
DescriptorProtos.FieldDescriptorProto.Builder
setOptions(DescriptorProtos.FieldOptions.Builder builderForValue)
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
DescriptorProtos.FieldDescriptorProto.Builder
setProto3Optional(boolean value)
optional bool proto3_optional = 17 [json_name = "proto3Optional"];
DescriptorProtos.FieldDescriptorProto.Builder
setType(DescriptorProtos.FieldDescriptorProto.Type value)
optional .google.protobuf.FieldDescriptorProto.Type type = 5 [json_name = "type"];
DescriptorProtos.FieldDescriptorProto.Builder
setTypeName(java.lang.String value)
optional string type_name = 6 [json_name = "typeName"];
DescriptorProtos.FieldDescriptorProto.Builder
setTypeNameBytes(ByteString value)
optional string type_name = 6 [json_name = "typeName"];
DescriptorProtos.FieldDescriptorProto.Builder
setUnknownFields(UnknownFieldSet unknownFields)
Set theUnknownFieldSet
for this message.-
Methods inherited from class com.google.protobuf.GeneratedMessageV3.Builder
addRepeatedField, clearField, clearOneof, clone, getAllFields, getField, getFieldBuilder, getOneofFieldDescriptor, getParentForChildren, getRepeatedField, getRepeatedFieldBuilder, getRepeatedFieldCount, getUnknownFields, getUnknownFieldSetBuilder, hasField, hasOneof, internalGetMapField, internalGetMutableMapField, isClean, markClean, mergeUnknownLengthDelimitedField, mergeUnknownVarintField, newBuilderForField, onBuilt, onChanged, parseUnknownField, setField, setRepeatedField, setUnknownFieldSetBuilder, setUnknownFieldsProto3
-
Methods inherited from class com.google.protobuf.AbstractMessage.Builder
findInitializationErrors, getInitializationErrorString, internalMergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, newUninitializedMessageException, toString
-
Methods inherited from class com.google.protobuf.AbstractMessageLite.Builder
addAll, addAll, mergeDelimitedFrom, mergeDelimitedFrom, mergeFrom, newUninitializedMessageException
-
Methods inherited from class java.lang.Object
equals, finalize, getClass, hashCode, notify, notifyAll, wait, wait, wait
-
Methods inherited from interface com.google.protobuf.Message.Builder
mergeDelimitedFrom, mergeDelimitedFrom
-
Methods inherited from interface com.google.protobuf.MessageLite.Builder
mergeFrom
-
Methods inherited from interface com.google.protobuf.MessageOrBuilder
findInitializationErrors, getAllFields, getField, getInitializationErrorString, getOneofFieldDescriptor, getRepeatedField, getRepeatedFieldCount, getUnknownFields, hasField, hasOneof
-
-
-
-
Method Detail
-
getDescriptor
public static final Descriptors.Descriptor getDescriptor()
-
internalGetFieldAccessorTable
protected GeneratedMessageV3.FieldAccessorTable internalGetFieldAccessorTable()
Description copied from class:GeneratedMessageV3.Builder
Get the FieldAccessorTable for this type. We can't have the message class pass this in to the constructor because of bootstrapping trouble with DescriptorProtos.- Specified by:
internalGetFieldAccessorTable
in classGeneratedMessageV3.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
-
clear
public DescriptorProtos.FieldDescriptorProto.Builder clear()
Description copied from class:GeneratedMessageV3.Builder
Called by the initialization and clear code paths to allow subclasses to reset any of their builtin fields back to the initial values.- Specified by:
clear
in interfaceMessage.Builder
- Specified by:
clear
in interfaceMessageLite.Builder
- Overrides:
clear
in classGeneratedMessageV3.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
-
getDescriptorForType
public Descriptors.Descriptor getDescriptorForType()
Description copied from interface:Message.Builder
Get the message's type's descriptor. SeeMessageOrBuilder.getDescriptorForType()
.- Specified by:
getDescriptorForType
in interfaceMessage.Builder
- Specified by:
getDescriptorForType
in interfaceMessageOrBuilder
- Overrides:
getDescriptorForType
in classGeneratedMessageV3.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
-
getDefaultInstanceForType
public DescriptorProtos.FieldDescriptorProto getDefaultInstanceForType()
Description copied from interface:MessageLiteOrBuilder
Get an instance of the type with no fields set. Because no fields are set, all getters for singular fields will return default values and repeated fields will appear empty. This may or may not be a singleton. This differs from thegetDefaultInstance()
method of generated message classes in that this method is an abstract method of theMessageLite
interface whereasgetDefaultInstance()
is a static method of a specific class. They return the same thing.- Specified by:
getDefaultInstanceForType
in interfaceMessageLiteOrBuilder
- Specified by:
getDefaultInstanceForType
in interfaceMessageOrBuilder
-
build
public DescriptorProtos.FieldDescriptorProto build()
Description copied from interface:MessageLite.Builder
Constructs the message based on the state of the Builder. Subsequent changes to the Builder will not affect the returned message.- Specified by:
build
in interfaceMessage.Builder
- Specified by:
build
in interfaceMessageLite.Builder
-
buildPartial
public DescriptorProtos.FieldDescriptorProto buildPartial()
Description copied from interface:MessageLite.Builder
LikeMessageLite.Builder.build()
, but does not throw an exception if the message is missing required fields. Instead, a partial message is returned. Subsequent changes to the Builder will not affect the returned message.- Specified by:
buildPartial
in interfaceMessage.Builder
- Specified by:
buildPartial
in interfaceMessageLite.Builder
-
mergeFrom
public DescriptorProtos.FieldDescriptorProto.Builder mergeFrom(Message other)
Description copied from interface:Message.Builder
Mergeother
into the message being built.other
must have the exact same type asthis
(i.e.getDescriptorForType() == other.getDescriptorForType()
).Merging occurs as follows. For each field:
* For singular primitive fields, if the field is set inother
, thenother
's value overwrites the value in this message.
* For singular message fields, if the field is set inother
, it is merged into the corresponding sub-message of this message using the same merging rules.
* For repeated fields, the elements inother
are concatenated with the elements in this message.
* For oneof groups, if the other message has one of the fields set, the group of this message is cleared and replaced by the field of the other message, so that the oneof constraint is preserved.This is equivalent to the
Message::MergeFrom
method in C++.- Specified by:
mergeFrom
in interfaceMessage.Builder
- Overrides:
mergeFrom
in classAbstractMessage.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
-
mergeFrom
public DescriptorProtos.FieldDescriptorProto.Builder mergeFrom(DescriptorProtos.FieldDescriptorProto other)
-
isInitialized
public final boolean isInitialized()
Description copied from interface:MessageLiteOrBuilder
Returns true if all required fields in the message and all embedded messages are set, false otherwise.- Specified by:
isInitialized
in interfaceMessageLiteOrBuilder
- Overrides:
isInitialized
in classGeneratedMessageV3.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
-
mergeFrom
public DescriptorProtos.FieldDescriptorProto.Builder mergeFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry) throws java.io.IOException
Description copied from interface:MessageLite.Builder
LikeMessageLite.Builder.mergeFrom(CodedInputStream)
, but also parses extensions. The extensions that you want to be able to parse must be registered inextensionRegistry
. Extensions not in the registry will be treated as unknown fields.- Specified by:
mergeFrom
in interfaceMessage.Builder
- Specified by:
mergeFrom
in interfaceMessageLite.Builder
- Overrides:
mergeFrom
in classAbstractMessage.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
- Throws:
InvalidProtocolBufferException
- the bytes read are not syntactically correct according to the protobuf wire format specification. The data is corrupt, incomplete, or was never a protobuf in the first place.java.io.IOException
- an I/O error reading from the stream
-
hasName
public boolean hasName()
optional string name = 1 [json_name = "name"];
- Specified by:
hasName
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the name field is set.
-
getName
public java.lang.String getName()
optional string name = 1 [json_name = "name"];
- Specified by:
getName
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The name.
-
getNameBytes
public ByteString getNameBytes()
optional string name = 1 [json_name = "name"];
- Specified by:
getNameBytes
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The bytes for name.
-
setName
public DescriptorProtos.FieldDescriptorProto.Builder setName(java.lang.String value)
optional string name = 1 [json_name = "name"];
- Parameters:
value
- The name to set.- Returns:
- This builder for chaining.
-
clearName
public DescriptorProtos.FieldDescriptorProto.Builder clearName()
optional string name = 1 [json_name = "name"];
- Returns:
- This builder for chaining.
-
setNameBytes
public DescriptorProtos.FieldDescriptorProto.Builder setNameBytes(ByteString value)
optional string name = 1 [json_name = "name"];
- Parameters:
value
- The bytes for name to set.- Returns:
- This builder for chaining.
-
hasNumber
public boolean hasNumber()
optional int32 number = 3 [json_name = "number"];
- Specified by:
hasNumber
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the number field is set.
-
getNumber
public int getNumber()
optional int32 number = 3 [json_name = "number"];
- Specified by:
getNumber
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The number.
-
setNumber
public DescriptorProtos.FieldDescriptorProto.Builder setNumber(int value)
optional int32 number = 3 [json_name = "number"];
- Parameters:
value
- The number to set.- Returns:
- This builder for chaining.
-
clearNumber
public DescriptorProtos.FieldDescriptorProto.Builder clearNumber()
optional int32 number = 3 [json_name = "number"];
- Returns:
- This builder for chaining.
-
hasLabel
public boolean hasLabel()
optional .google.protobuf.FieldDescriptorProto.Label label = 4 [json_name = "label"];
- Specified by:
hasLabel
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the label field is set.
-
getLabel
public DescriptorProtos.FieldDescriptorProto.Label getLabel()
optional .google.protobuf.FieldDescriptorProto.Label label = 4 [json_name = "label"];
- Specified by:
getLabel
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The label.
-
setLabel
public DescriptorProtos.FieldDescriptorProto.Builder setLabel(DescriptorProtos.FieldDescriptorProto.Label value)
optional .google.protobuf.FieldDescriptorProto.Label label = 4 [json_name = "label"];
- Parameters:
value
- The label to set.- Returns:
- This builder for chaining.
-
clearLabel
public DescriptorProtos.FieldDescriptorProto.Builder clearLabel()
optional .google.protobuf.FieldDescriptorProto.Label label = 4 [json_name = "label"];
- Returns:
- This builder for chaining.
-
hasType
public boolean hasType()
optional .google.protobuf.FieldDescriptorProto.Type type = 5 [json_name = "type"];
- Specified by:
hasType
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the type field is set.
-
getType
public DescriptorProtos.FieldDescriptorProto.Type getType()
optional .google.protobuf.FieldDescriptorProto.Type type = 5 [json_name = "type"];
- Specified by:
getType
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The type.
-
setType
public DescriptorProtos.FieldDescriptorProto.Builder setType(DescriptorProtos.FieldDescriptorProto.Type value)
optional .google.protobuf.FieldDescriptorProto.Type type = 5 [json_name = "type"];
- Parameters:
value
- The type to set.- Returns:
- This builder for chaining.
-
clearType
public DescriptorProtos.FieldDescriptorProto.Builder clearType()
optional .google.protobuf.FieldDescriptorProto.Type type = 5 [json_name = "type"];
- Returns:
- This builder for chaining.
-
hasTypeName
public boolean hasTypeName()
optional string type_name = 6 [json_name = "typeName"];
- Specified by:
hasTypeName
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the typeName field is set.
-
getTypeName
public java.lang.String getTypeName()
optional string type_name = 6 [json_name = "typeName"];
- Specified by:
getTypeName
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The typeName.
-
getTypeNameBytes
public ByteString getTypeNameBytes()
optional string type_name = 6 [json_name = "typeName"];
- Specified by:
getTypeNameBytes
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The bytes for typeName.
-
setTypeName
public DescriptorProtos.FieldDescriptorProto.Builder setTypeName(java.lang.String value)
optional string type_name = 6 [json_name = "typeName"];
- Parameters:
value
- The typeName to set.- Returns:
- This builder for chaining.
-
clearTypeName
public DescriptorProtos.FieldDescriptorProto.Builder clearTypeName()
optional string type_name = 6 [json_name = "typeName"];
- Returns:
- This builder for chaining.
-
setTypeNameBytes
public DescriptorProtos.FieldDescriptorProto.Builder setTypeNameBytes(ByteString value)
optional string type_name = 6 [json_name = "typeName"];
- Parameters:
value
- The bytes for typeName to set.- Returns:
- This builder for chaining.
-
hasExtendee
public boolean hasExtendee()
optional string extendee = 2 [json_name = "extendee"];
- Specified by:
hasExtendee
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the extendee field is set.
-
getExtendee
public java.lang.String getExtendee()
optional string extendee = 2 [json_name = "extendee"];
- Specified by:
getExtendee
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The extendee.
-
getExtendeeBytes
public ByteString getExtendeeBytes()
optional string extendee = 2 [json_name = "extendee"];
- Specified by:
getExtendeeBytes
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The bytes for extendee.
-
setExtendee
public DescriptorProtos.FieldDescriptorProto.Builder setExtendee(java.lang.String value)
optional string extendee = 2 [json_name = "extendee"];
- Parameters:
value
- The extendee to set.- Returns:
- This builder for chaining.
-
clearExtendee
public DescriptorProtos.FieldDescriptorProto.Builder clearExtendee()
optional string extendee = 2 [json_name = "extendee"];
- Returns:
- This builder for chaining.
-
setExtendeeBytes
public DescriptorProtos.FieldDescriptorProto.Builder setExtendeeBytes(ByteString value)
optional string extendee = 2 [json_name = "extendee"];
- Parameters:
value
- The bytes for extendee to set.- Returns:
- This builder for chaining.
-
hasDefaultValue
public boolean hasDefaultValue()
optional string default_value = 7 [json_name = "defaultValue"];
- Specified by:
hasDefaultValue
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the defaultValue field is set.
-
getDefaultValue
public java.lang.String getDefaultValue()
optional string default_value = 7 [json_name = "defaultValue"];
- Specified by:
getDefaultValue
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The defaultValue.
-
getDefaultValueBytes
public ByteString getDefaultValueBytes()
optional string default_value = 7 [json_name = "defaultValue"];
- Specified by:
getDefaultValueBytes
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The bytes for defaultValue.
-
setDefaultValue
public DescriptorProtos.FieldDescriptorProto.Builder setDefaultValue(java.lang.String value)
optional string default_value = 7 [json_name = "defaultValue"];
- Parameters:
value
- The defaultValue to set.- Returns:
- This builder for chaining.
-
clearDefaultValue
public DescriptorProtos.FieldDescriptorProto.Builder clearDefaultValue()
optional string default_value = 7 [json_name = "defaultValue"];
- Returns:
- This builder for chaining.
-
setDefaultValueBytes
public DescriptorProtos.FieldDescriptorProto.Builder setDefaultValueBytes(ByteString value)
optional string default_value = 7 [json_name = "defaultValue"];
- Parameters:
value
- The bytes for defaultValue to set.- Returns:
- This builder for chaining.
-
hasOneofIndex
public boolean hasOneofIndex()
optional int32 oneof_index = 9 [json_name = "oneofIndex"];
- Specified by:
hasOneofIndex
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the oneofIndex field is set.
-
getOneofIndex
public int getOneofIndex()
optional int32 oneof_index = 9 [json_name = "oneofIndex"];
- Specified by:
getOneofIndex
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The oneofIndex.
-
setOneofIndex
public DescriptorProtos.FieldDescriptorProto.Builder setOneofIndex(int value)
optional int32 oneof_index = 9 [json_name = "oneofIndex"];
- Parameters:
value
- The oneofIndex to set.- Returns:
- This builder for chaining.
-
clearOneofIndex
public DescriptorProtos.FieldDescriptorProto.Builder clearOneofIndex()
optional int32 oneof_index = 9 [json_name = "oneofIndex"];
- Returns:
- This builder for chaining.
-
hasJsonName
public boolean hasJsonName()
optional string json_name = 10 [json_name = "jsonName"];
- Specified by:
hasJsonName
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the jsonName field is set.
-
getJsonName
public java.lang.String getJsonName()
optional string json_name = 10 [json_name = "jsonName"];
- Specified by:
getJsonName
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The jsonName.
-
getJsonNameBytes
public ByteString getJsonNameBytes()
optional string json_name = 10 [json_name = "jsonName"];
- Specified by:
getJsonNameBytes
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The bytes for jsonName.
-
setJsonName
public DescriptorProtos.FieldDescriptorProto.Builder setJsonName(java.lang.String value)
optional string json_name = 10 [json_name = "jsonName"];
- Parameters:
value
- The jsonName to set.- Returns:
- This builder for chaining.
-
clearJsonName
public DescriptorProtos.FieldDescriptorProto.Builder clearJsonName()
optional string json_name = 10 [json_name = "jsonName"];
- Returns:
- This builder for chaining.
-
setJsonNameBytes
public DescriptorProtos.FieldDescriptorProto.Builder setJsonNameBytes(ByteString value)
optional string json_name = 10 [json_name = "jsonName"];
- Parameters:
value
- The bytes for jsonName to set.- Returns:
- This builder for chaining.
-
hasOptions
public boolean hasOptions()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
- Specified by:
hasOptions
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the options field is set.
-
getOptions
public DescriptorProtos.FieldOptions getOptions()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
- Specified by:
getOptions
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The options.
-
setOptions
public DescriptorProtos.FieldDescriptorProto.Builder setOptions(DescriptorProtos.FieldOptions value)
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
-
setOptions
public DescriptorProtos.FieldDescriptorProto.Builder setOptions(DescriptorProtos.FieldOptions.Builder builderForValue)
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
-
mergeOptions
public DescriptorProtos.FieldDescriptorProto.Builder mergeOptions(DescriptorProtos.FieldOptions value)
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
-
clearOptions
public DescriptorProtos.FieldDescriptorProto.Builder clearOptions()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
-
getOptionsBuilder
public DescriptorProtos.FieldOptions.Builder getOptionsBuilder()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
-
getOptionsOrBuilder
public DescriptorProtos.FieldOptionsOrBuilder getOptionsOrBuilder()
optional .google.protobuf.FieldOptions options = 8 [json_name = "options"];
- Specified by:
getOptionsOrBuilder
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
-
hasProto3Optional
public boolean hasProto3Optional()
optional bool proto3_optional = 17 [json_name = "proto3Optional"];
- Specified by:
hasProto3Optional
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- Whether the proto3Optional field is set.
-
getProto3Optional
public boolean getProto3Optional()
optional bool proto3_optional = 17 [json_name = "proto3Optional"];
- Specified by:
getProto3Optional
in interfaceDescriptorProtos.FieldDescriptorProtoOrBuilder
- Returns:
- The proto3Optional.
-
setProto3Optional
public DescriptorProtos.FieldDescriptorProto.Builder setProto3Optional(boolean value)
optional bool proto3_optional = 17 [json_name = "proto3Optional"];
- Parameters:
value
- The proto3Optional to set.- Returns:
- This builder for chaining.
-
clearProto3Optional
public DescriptorProtos.FieldDescriptorProto.Builder clearProto3Optional()
optional bool proto3_optional = 17 [json_name = "proto3Optional"];
- Returns:
- This builder for chaining.
-
setUnknownFields
public final DescriptorProtos.FieldDescriptorProto.Builder setUnknownFields(UnknownFieldSet unknownFields)
Description copied from interface:Message.Builder
Set theUnknownFieldSet
for this message.- Specified by:
setUnknownFields
in interfaceMessage.Builder
- Overrides:
setUnknownFields
in classGeneratedMessageV3.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
-
mergeUnknownFields
public final DescriptorProtos.FieldDescriptorProto.Builder mergeUnknownFields(UnknownFieldSet unknownFields)
Description copied from interface:Message.Builder
Merge some unknown fields into theUnknownFieldSet
for this message.- Specified by:
mergeUnknownFields
in interfaceMessage.Builder
- Overrides:
mergeUnknownFields
in classGeneratedMessageV3.Builder<DescriptorProtos.FieldDescriptorProto.Builder>
-
-