    Indicate for a state estimation which tap changers are to be estimated (i.e. their tap positions should be outputs). If a tap changer is not to be estimated, it should not be changed during a state estimation (i.e its tap position is only an input).
    Author:
    Miora Ralambotiana
    • Method Detail

      • shouldEstimateRatioTapChanger

        boolean shouldEstimateRatioTapChanger()
        Return true if the ratio tap changer of the extended two windings transformer is to be estimated during a state estimation. Else, return false.
      • shouldEstimatePhaseTapChanger

        boolean shouldEstimatePhaseTapChanger()
        Return true if the phase tap changer of the extended two windings transformer is to be estimated during a state estimation. Else, return false.
      • shouldEstimateRatioTapChanger

        TwoWindingsTransformerToBeEstimated shouldEstimateRatioTapChanger​(boolean toBeEstimated)
        Specify if the ratio tap changer of the extended two windings transformer is to be estimated during a state estimation.
      • shouldEstimatePhaseTapChanger

        TwoWindingsTransformerToBeEstimated shouldEstimatePhaseTapChanger​(boolean toBeEstimated)