Package com.powsybl.iidm.network
Interface HvdcLine
-
- All Superinterfaces:
Extendable<HvdcLine>
,Identifiable<HvdcLine>
- All Known Implementing Classes:
HvdcLineAdapter
public interface HvdcLine extends Identifiable<HvdcLine>
A HVDC line connected to two HVDC converters on DC side. It has to be connected to the same
subclass.HvdcConverterStation
Characteristics
Attribute Type Unit Required Defaut value Description Id String - yes - Unique identifier of the HVDC line Name String - yes - Human-readable name of the HVDC line R double Ω yes - The resistance of the HVDC line ConvertersMode ConvertersMode - yes - The converter's mode NominalV double kV yes - The nominal voltage ActivePowerSetpoint double MW yes - The active power setpoint MaxP double MW yes - The maximum active power ConverterStationId1 String - yes - The ID of the HVDC converter station connected on side 1 ConverterStationId2 String - yes - The ID of the HVDC converter station connected on side 2 - Author:
- Geoffroy Jamgotchian
, Mathieu Bague
-
-
Nested Class Summary
Nested Classes Modifier and Type Interface Description static class
HvdcLine.ConvertersMode
Converters mode used to known the sign of the active power of the HVDC line.static class
HvdcLine.Side
-
Method Summary
All Methods Instance Methods Abstract Methods Default Methods Modifier and Type Method Description double
getActivePowerSetpoint()
Get the active power setpoint (in MW).HvdcLine.ConvertersMode
getConvertersMode()
Get converters mode.default HvdcConverterStation<?>
getConverterStation(HvdcLine.Side side)
Get the HVDC converter station connected to a sideHvdcConverterStation<?>
getConverterStation1()
Get the HVDC converter station connected on side 1.HvdcConverterStation<?>
getConverterStation2()
Get the HVDC converter station connected on side 2.double
getMaxP()
Get the maximum active power (in MW).Network
getNetwork()
Get the network this HVDC line belongs.double
getNominalV()
Get the nominal voltage (in Kv).double
getR()
Get resistance (in Ω) of the line.default IdentifiableType
getType()
Get identifiable type.void
remove()
Remove the HVDC lineHvdcLine
setActivePowerSetpoint(double activePowerSetpoint)
Set the active power setpoint (in MW).HvdcLine
setConvertersMode(HvdcLine.ConvertersMode mode)
Change converters mode.HvdcLine
setMaxP(double maxP)
Set the maximum active power (in MW).HvdcLine
setNominalV(double nominalV)
Set the nominal voltage.HvdcLine
setR(double r)
Set the resistance (in Ω) of the line.-
Methods inherited from interface com.powsybl.commons.extensions.Extendable
addExtension, getExtension, getExtensionByName, getExtensions, getImplementationName, newExtension, removeExtension
-
Methods inherited from interface com.powsybl.iidm.network.Identifiable
addAlias, addAlias, addAlias, addAlias, getAliases, getAliasFromType, getAliasType, getId, getName, getNameOrId, getOptionalName, getProperties, getProperty, getProperty, getPropertyNames, hasAliases, hasProperty, hasProperty, isFictitious, removeAlias, removeProperty, setFictitious, setName, setProperty
-
-
-
-
Method Detail
-
getNetwork
Network getNetwork()
Get the network this HVDC line belongs.- Specified by:
getNetwork
in interfaceIdentifiable<HvdcLine>
- Returns:
- the network this HVDC line belongs
-
getConvertersMode
HvdcLine.ConvertersMode getConvertersMode()
Get converters mode.- Returns:
- converters mode
-
setConvertersMode
HvdcLine setConvertersMode(HvdcLine.ConvertersMode mode)
Change converters mode.- Parameters:
mode
- converters mode- Returns:
- the station itself to allow method chaining.
-
getR
double getR()
Get resistance (in Ω) of the line.- Returns:
- the resistance of the line
-
setR
HvdcLine setR(double r)
Set the resistance (in Ω) of the line.- Parameters:
r
- the resistance of the line- Returns:
- the HVDC line itself to allow method chaining
-
getNominalV
double getNominalV()
Get the nominal voltage (in Kv).- Returns:
- the nominal voltage.
-
setNominalV
HvdcLine setNominalV(double nominalV)
Set the nominal voltage.- Parameters:
nominalV
- the nominal voltage.- Returns:
- the HVDC line itself to allow method chaining
-
getActivePowerSetpoint
double getActivePowerSetpoint()
Get the active power setpoint (in MW).- Returns:
- the active power setpoint
-
setActivePowerSetpoint
HvdcLine setActivePowerSetpoint(double activePowerSetpoint)
Set the active power setpoint (in MW).- Parameters:
activePowerSetpoint
- the active power setpoint- Returns:
- the HVDC line itself to allow method chaining
-
getMaxP
double getMaxP()
Get the maximum active power (in MW).- Returns:
- the maximum active power
-
setMaxP
HvdcLine setMaxP(double maxP)
Set the maximum active power (in MW).- Parameters:
maxP
- the maximum active power- Returns:
- the HVDC line itself to allow method chaining
-
getConverterStation
default HvdcConverterStation<?> getConverterStation(HvdcLine.Side side)
Get the HVDC converter station connected to a side- Returns:
- the HVDC converter station connected to the side
-
getConverterStation1
HvdcConverterStation<?> getConverterStation1()
Get the HVDC converter station connected on side 1.- Returns:
- the HVDC converter station connected on side 1
-
getConverterStation2
HvdcConverterStation<?> getConverterStation2()
Get the HVDC converter station connected on side 2.- Returns:
- the HVDC converter station connected on side 2
-
remove
void remove()
Remove the HVDC line
-
getType
default IdentifiableType getType()
Description copied from interface:Identifiable
Get identifiable type.- Specified by:
getType
in interfaceIdentifiable<HvdcLine>